CE-LIF coupled with flow cytometry for high-throughput quantitation of fluorophores in single intact cells

文献类型:期刊论文

作者Xiao, Hua; Li, Xin; Zou, Hanfa; Yang, Ling; Wang, Yulin; Wang, Hailin; Le, X. Chris
刊名electrophoresis
出版日期2006-09-01
卷号27期号:17页码:3452-3459
关键词apparent permeability coefficient capillary electrophoresis flow cytometry single cell analysis transport rate
ISSN号0173-0835
产权排序1;1
通讯作者邹汉法
英文摘要we report a method of coupled ce-lif detection with flow cytometry for high-throughput determination and quantitation of fluorophores in single intact k562/s (ks) cells. the membrane properties of ks cell including fluophore transport rate and apparent permeability coefficient were further quantitatively characterized. the method has advantages for accurate quantitation and unique capacity of high-throughput analysis. the strategy will be useful for the quantitation of fluorophores in the intact cells, such as measurement of multidrug resistance, quantitation of specific protein expression, and quantitative characterization of protein and enzyme functions.
WOS标题词science & technology ; life sciences & biomedicine ; physical sciences
类目[WOS]biochemical research methods ; chemistry, analytical
研究领域[WOS]biochemistry & molecular biology ; chemistry
关键词[WOS]induced fluorescence detection ; capillary-electrophoresis ; multidrug-resistance ; caco-2 monolayers ; mammalian-cells ; microscopy ; transport ; effluxes ; protein
收录类别SCI
原文出处true
语种英语
WOS记录号WOS:000240585900016
公开日期2010-11-30
源URL[http://159.226.238.44/handle/321008/97219]  
专题大连化学物理研究所_中国科学院大连化学物理研究所
作者单位1.Chinese Acad Sci, Dalian Inst Chem Phys, Natl Chromatog R&A Ctr, Dalian 116023, Peoples R China
2.Chinese Acad Sci, Dalian Inst Chem Phys, Lab Pharmaceut Resource Discovery, Dalian, Peoples R China
3.Univ Alberta, Fac Med, Dept Publ Hlth Sci, Edmonton, AB, Canada
推荐引用方式
GB/T 7714
Xiao, Hua,Li, Xin,Zou, Hanfa,et al. CE-LIF coupled with flow cytometry for high-throughput quantitation of fluorophores in single intact cells[J]. electrophoresis,2006,27(17):3452-3459.
APA Xiao, Hua.,Li, Xin.,Zou, Hanfa.,Yang, Ling.,Wang, Yulin.,...&Le, X. Chris.(2006).CE-LIF coupled with flow cytometry for high-throughput quantitation of fluorophores in single intact cells.electrophoresis,27(17),3452-3459.
MLA Xiao, Hua,et al."CE-LIF coupled with flow cytometry for high-throughput quantitation of fluorophores in single intact cells".electrophoresis 27.17(2006):3452-3459.

入库方式: OAI收割