HH2型土壤湿度计测定土壤含水量的标定研究
文献类型:期刊论文
作者 | 甘卓亭 ; 刘文兆 |
刊名 | 干旱地区农业研究
![]() |
出版日期 | 2005 |
期号 | 4页码:69-72 |
其他题名 | Calibration on measurement of soil water content using SMS2 Soil Moisture Probe and HH2 Meter |
合作状况 | 其它 |
中文摘要 | 就HH2型土壤湿度计在黄土高原沟壑区黑垆土表层的应用进行了标定研究,分析了HH2测量的准确性,各容重标定曲线的精度和灵敏度。结果表明:在各种容重条件下用HH2测量土壤水分,输出电压的变异系数小于6%,仪器的准确性较高。线性标定方程斜率a随容重的增大而增加,常数b则相反。容重标定曲线对HH2的可调参数a0、a1影响较小。当土壤水分含量为18%~19%时,不同容重的标定曲线的差别最低。 |
英文摘要 | The calibration of SMS2 Soil Moisture Probe and HH2 Meter (HH2) was studied in surface stratum of Heilu soil in the tableland and gully region of Loess Plateau, and the veracity of HH2 and the precisions and sensitivities of different calibration curves were analyzed. The results demonstrate that the CV of voltage by HH2 under different soil densities is less than 6%, and the measurements by HH2 are credible. The slope a of linear regression is increased with the accretion of soil densities, but the constan... |
语种 | 中文 |
公开日期 | 2010-11-14 |
源URL | [http://ir.iswc.ac.cn/handle/361005/1650] ![]() |
专题 | 水土保持研究所_水保所知识产出(1956-2013) |
推荐引用方式 GB/T 7714 | 甘卓亭,刘文兆. HH2型土壤湿度计测定土壤含水量的标定研究[J]. 干旱地区农业研究,2005(4):69-72. |
APA | 甘卓亭,&刘文兆.(2005).HH2型土壤湿度计测定土壤含水量的标定研究.干旱地区农业研究(4),69-72. |
MLA | 甘卓亭,et al."HH2型土壤湿度计测定土壤含水量的标定研究".干旱地区农业研究 .4(2005):69-72. |