中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
A dual-readout chemiluminescent-gold lateral flow test for multiplex and ultrasensitive detection of disease biomarkers in real samples

文献类型:期刊论文

作者Chen, Yiping1,2; Sun, Jiashu1,2; Xianyu, Yunlei1,2; Yin, Binfeng1,2; Niu, Yajing1,2; Wang, Songbai1,2,5; Cao, Fengjing1,2; Zhang, Xiaoqing1,2; Wang, Yu3,4; Jiang, Xingyu1,2
刊名Nanoscale
出版日期2016
卷号8期号:33页码:15205-15212
ISSN号2040-3364
DOI10.1039/c6nr04017a
通讯作者Jiang, xingyu(xingyujiang@nanoctr.cn)
英文摘要Even though the gold lateral flow test (glft) is low-cost and allows for point-of-care testing (poct), its intrinsic limitations including low sensitivity and incapability of quantification significantly hinder the clinical application of glft for assaying disease biomarkers. to improve the performance of the glft without sacrificing its simplicity, we develop a chemiluminescent-gold lateral flow test (c-mode glft) for quantitative and multiplex detection of disease biomarkers with an ultrahigh sensitivity at a picomolar level. horseradish peroxidase (hrp) and antibody (ab) are simultaneously labeled onto the surface of gold nanoparticles (aunps) to achieve a dual-readout (chemiluminescent and visual, c&v-mode glft). a red color appears at the test line caused by the accumulation of captured aunps in the presence of targets, while hrp on the surface of aunps catalyzes the chemiluminescence reaction of luminol to amplify the signal. c-mode glft is successfully used for detecting tumor biomarkers (alpha fetoprotein, afp, and carcino embryonic antigen, cea) and bacterial infection biomarkers (procalcitonin, pct) in serum samples as well as whole blood. the excellent features of c-mode glft such as straightforward operation, ultrahigh sensitivity and quantitative detection, make it a promising platform for poct of a variety of disease biomarkers in real samples.
WOS关键词RESONANCE ENERGY-TRANSFER ; SENSITIVE DETECTION ; IMMUNOASSAY ; BIOSENSOR ; NANOPARTICLES ; IMMUNOSENSOR ; PLATFORM ; STRIP ; ARRAY ; ASSAY
WOS研究方向Chemistry ; Science & Technology - Other Topics ; Materials Science ; Physics
WOS类目Chemistry, Multidisciplinary ; Nanoscience & Nanotechnology ; Materials Science, Multidisciplinary ; Physics, Applied
语种英语
WOS记录号WOS:000382068000015
出版者ROYAL SOC CHEMISTRY
URI标识http://www.irgrid.ac.cn/handle/1471x/2176588
专题高能物理研究所
通讯作者Jiang, Xingyu
作者单位1.Natl Ctr NanoSci & Technol, Beijing Engn Res Ctr BioNanotechnol, Beijing 100190, Peoples R China
2.Natl Ctr NanoSci & Technol, CAS Key Lab Biol Effects Nanomat & Nanosafety, Beijing 100190, Peoples R China
3.Capital Med Univ, Beijing Inst Trop Med, 95 Yongan Rd, Beijing 100050, Peoples R China
4.Capital Med Univ, Beijing Friendship Hosp, 95 Yongan Rd, Beijing 100050, Peoples R China
5.Shanxi Univ, Res Ctr Environm Sci & Engn, Dept Chem & Chem Engn, Taiyuan 030006, Peoples R China
推荐引用方式
GB/T 7714
Chen, Yiping,Sun, Jiashu,Xianyu, Yunlei,et al. A dual-readout chemiluminescent-gold lateral flow test for multiplex and ultrasensitive detection of disease biomarkers in real samples[J]. Nanoscale,2016,8(33):15205-15212.
APA Chen, Yiping.,Sun, Jiashu.,Xianyu, Yunlei.,Yin, Binfeng.,Niu, Yajing.,...&Jiang, Xingyu.(2016).A dual-readout chemiluminescent-gold lateral flow test for multiplex and ultrasensitive detection of disease biomarkers in real samples.Nanoscale,8(33),15205-15212.
MLA Chen, Yiping,et al."A dual-readout chemiluminescent-gold lateral flow test for multiplex and ultrasensitive detection of disease biomarkers in real samples".Nanoscale 8.33(2016):15205-15212.

入库方式: iSwitch采集

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。