Two-dimensional imaging triple-gem detector with resistive anode readout
文献类型:期刊论文
作者 | Ju, X. D.1,2; Dong, M. Y.1,2,3; Zhao, Y. C.2; Zhou, C. X.2; Dong, J.1,2; Zhao, Y. B.1,2; Zhang, H. Y.1,2; OuYang, Q.1,2,3 |
刊名 | Journal of instrumentation
![]() |
出版日期 | 2017-10-01 |
卷号 | 12页码:13 |
关键词 | Electronic detector readout concepts (gas, liquid) Gaseous imaging and tracking detectors Micropattern gaseous detectors (msgc, gem, thgem, rethgem, mhsp, micropic, micromegas, ingrid, etc) X-ray detectors |
ISSN号 | 1748-0221 |
DOI | 10.1088/1748-0221/12/10/p10008 |
通讯作者 | Dong, m. y.(dongmy@ihep.ac.cn) |
英文摘要 | The resistive anode readout facilitates a good spatial resolution with a large reduction of the electronics channels. the application of such readout method on a 100 x 100 mm(2) triple-gem detector is presented. the detector anode covers 88 x 88 mm(2) sensitive area and consists of 11 x 11 resistive cells with the cell dimension of 8 x 8 mm(2). the detector has been tested by using a fe-55 source (5.9 kev) and an x-ray tube (8 kev). it is found that the spatial resolution (sigma) is about 120 mu m with the intrinsic detector response better than 100 mu m. the position nonlinearity of the whole sensitive area is better than 3%. the energy resolution for 5.9 kev x rays is around 20% (fwhm) and the gain nonuniformity between different cells is better than 7%. the detector shows a quite good 2d imaging performance as well. especially, the detector costs only half of the number of the electronics channels compared with that using the 2d strip readout. |
WOS关键词 | SENSITIVE SILICON DETECTORS ; GASEOUS DETECTORS ; PIXEL DETECTOR ; GAS DETECTORS ; POSITION ; RECONSTRUCTION ; PERFORMANCE |
WOS研究方向 | Instruments & Instrumentation |
WOS类目 | Instruments & Instrumentation |
语种 | 英语 |
WOS记录号 | WOS:000414167100008 |
出版者 | IOP PUBLISHING LTD |
URI标识 | http://www.irgrid.ac.cn/handle/1471x/2176879 |
专题 | 高能物理研究所 |
通讯作者 | Dong, M. Y. |
作者单位 | 1.State Key Lab Particle Detect & Elect, Beijing, Peoples R China 2.Chinese Acad Sci, Inst High Energy Phys, Beijing, Peoples R China 3.Univ Chinese Acad Sci, Beijing, Peoples R China |
推荐引用方式 GB/T 7714 | Ju, X. D.,Dong, M. Y.,Zhao, Y. C.,et al. Two-dimensional imaging triple-gem detector with resistive anode readout[J]. Journal of instrumentation,2017,12:13. |
APA | Ju, X. D..,Dong, M. Y..,Zhao, Y. C..,Zhou, C. X..,Dong, J..,...&OuYang, Q..(2017).Two-dimensional imaging triple-gem detector with resistive anode readout.Journal of instrumentation,12,13. |
MLA | Ju, X. D.,et al."Two-dimensional imaging triple-gem detector with resistive anode readout".Journal of instrumentation 12(2017):13. |
入库方式: iSwitch采集
来源:高能物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。