Portable calibration node for lhaaso-km2a detector array
文献类型:期刊论文
作者 | Li, Hongming1; Gong, Guanghua1,2,3; Li, Jianmin1 |
刊名 | Ieee transactions on nuclear science
![]() |
出版日期 | 2017-06-01 |
卷号 | 64期号:6页码:1363-1366 |
关键词 | Calibration Time to digital converter (tdc) White rabbit (wr) |
ISSN号 | 0018-9499 |
DOI | 10.1109/tns.2017.2654491 |
通讯作者 | Gong, guanghua(ggh@tsinghua.edu.cn) |
英文摘要 | Aiming to high sensitivity and wide spectrum of cosmic ray detection, the 1 km(2) complex array of large high altitude air shower observatory (lhaaso-km2a) project consists of over 7000 detectors of different types. to reconstruct the air shower events with high angular resolution, timestamps of all detector electronics and digitizers should be aligned better than 500 ps rms. white rabbit (wr) technology, a fully deterministic ethernet-based network with subnanosecond synchronization accuracy and picoseconds precision, is applied to build the dedicated data and timing network. to guarantee the overall synchronization precision, individual calibration of each wr node is essential to compensate device deviation. this paper talks about autocalibration procedure of all nodes in the lhaaso-km2a wr network using the portable calibration node (pcn). usage of the pcn in deploying the detectors array and validating synchronization performance of the wr network is also discussed. |
WOS研究方向 | Engineering ; Nuclear Science & Technology |
WOS类目 | Engineering, Electrical & Electronic ; Nuclear Science & Technology |
语种 | 英语 |
WOS记录号 | WOS:000404973000026 |
出版者 | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC |
URI标识 | http://www.irgrid.ac.cn/handle/1471x/2177255 |
专题 | 高能物理研究所 |
通讯作者 | Gong, Guanghua |
作者单位 | 1.Tsinghua Univ, Key Lab Particle & Radiat Imaging, Minist Educ, Beijing 100084, Peoples R China 2.Chinese Acad Sci, Inst High Energy Phys, State Key Lab Particle Detect & Elect, Beijing 100049, Peoples R China 3.Univ Sci & Technol China, Wuhan 430074, Peoples R China |
推荐引用方式 GB/T 7714 | Li, Hongming,Gong, Guanghua,Li, Jianmin. Portable calibration node for lhaaso-km2a detector array[J]. Ieee transactions on nuclear science,2017,64(6):1363-1366. |
APA | Li, Hongming,Gong, Guanghua,&Li, Jianmin.(2017).Portable calibration node for lhaaso-km2a detector array.Ieee transactions on nuclear science,64(6),1363-1366. |
MLA | Li, Hongming,et al."Portable calibration node for lhaaso-km2a detector array".Ieee transactions on nuclear science 64.6(2017):1363-1366. |
入库方式: iSwitch采集
来源:高能物理研究所
浏览0