Anisotropic total variation minimization approach in in-line phase-contrast tomography and its application to correction of ring artifacts

文献类型:期刊论文

作者Ji, Dong-Jiang1,2; Qu, Gang-Rong1,3; Hu, Chun-Hong4; Liu, Bao-Dong5,6,7; Jian, Jian-Bo8; Guo, Xiao-Kun9
刊名Chinese physics b
出版日期2017-06-01
卷号26期号:6页码:8
关键词Sart Anisotropic tv In-line phase-contrast
ISSN号1674-1056
DOI10.1088/1674-1056/26/6/060701
通讯作者Qu, gang-rong(grqu@bjtu.edu.cn)
英文摘要In-line phase-contrast computed tomography (il-pc-ct) imaging is a new physical and biochemical imaging method. il-pc-ct has advantages compared to absorption ct when imaging soft tissues. in practical applications, ring artifacts which will reduce the image quality are commonly encountered in il-pc-ct, and numerous correction methods exist to either pre-process the sinogram or post-process the reconstructed image. in this study, we develop an il-pc-ct reconstruction method based on anisotropic total variation (tv) minimization. using this method, the ring artifacts are corrected during the reconstruction process. this method is compared with two methods: a sinogram preprocessing correction technique based on wavelet-fft filter and a reconstruction method based on isotropic tv. the correction results show that the proposed method can reduce visible ring artifacts while preserving the liver section details for real liver section synchrotron data.
WOS关键词IMAGE-RECONSTRUCTION ; REMOVAL ; CT ; MODEL
WOS研究方向Physics
WOS类目Physics, Multidisciplinary
语种英语
WOS记录号WOS:000403058100001
出版者IOP PUBLISHING LTD
URI标识http://www.irgrid.ac.cn/handle/1471x/2177280
专题高能物理研究所
通讯作者Qu, Gang-Rong
作者单位1.Beijing Jiaotong Univ, Sch Sci, Beijing 100044, Peoples R China
2.Tianjin Univ Technol & Educ, Sch Sci, Tianjin 300222, Peoples R China
3.Beijing Ctr Math & Informat Interdisciplinary Sci, Beijing 100048, Peoples R China
4.Tianjin Med Univ, Coll Biomed Engn, Tianjin 300070, Peoples R China
5.Chinese Acad Sci, Inst High Energy Phys, Div Nucl Technol & Applicat, Beijing 100049, Peoples R China
6.Beijing Engn Res Ctr Radiog Tech & Equipment, Beijing 100049, Peoples R China
7.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
8.Tianjin Med Univ, Radiat Oncol Dept, Gen Hosp, Tianjin 300052, Peoples R China
9.Tianjin Med Univ, Hosp 2, Tianjin 300070, Peoples R China
推荐引用方式
GB/T 7714
Ji, Dong-Jiang,Qu, Gang-Rong,Hu, Chun-Hong,et al. Anisotropic total variation minimization approach in in-line phase-contrast tomography and its application to correction of ring artifacts[J]. Chinese physics b,2017,26(6):8.
APA Ji, Dong-Jiang,Qu, Gang-Rong,Hu, Chun-Hong,Liu, Bao-Dong,Jian, Jian-Bo,&Guo, Xiao-Kun.(2017).Anisotropic total variation minimization approach in in-line phase-contrast tomography and its application to correction of ring artifacts.Chinese physics b,26(6),8.
MLA Ji, Dong-Jiang,et al."Anisotropic total variation minimization approach in in-line phase-contrast tomography and its application to correction of ring artifacts".Chinese physics b 26.6(2017):8.

入库方式: iSwitch采集

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。