Mechanical stability of the cms strip tracker measured with a laser alignment system

文献类型:期刊论文

作者Sirunyan, A. M.1; Tumasyan, A.1; Adam, W.2; Asilar, E.2; Bergauer, T.2; Brandstetter, J.2; Brondolin, E.2; Dragicevic, M.2; Eroe, J.2; Flechl, M.2
刊名Journal of instrumentation
出版日期2017-04-01
卷号12页码:39
ISSN号1748-0221
关键词Detector alignment and calibration methods (lasers, sources, particle-beams) Large detector systems for particle and astroparticle physics Particle tracking detectors Particle tracking detectors (solid-state detectors)
DOI10.1088/1748-0221/12/04/p04023
通讯作者Sirunyan, a. m.()
英文摘要The cms tracker consists of 206m(2) of silicon strip sensors assembled on carbon fibre composite structures and is designed for operation in the temperature range from -25 to + 25 degrees c. the mechanical stability of tracker components during physics operation was monitored with a few mu m resolution using a dedicated laser alignment system as well as particle tracks from cosmic rays and hadron-hadron collisions. during the lhc operational period of 2011-2013 at stable temperatures, the components of the tracker were observed to experience relative movements of less than 30 mu m. in addition, temperature variations were found to cause displacements of tracker structures of about 2 mu m/degrees c, which largely revert to their initial positions when the temperature is restored to its original value.
WOS关键词DETECTOR
WOS研究方向Instruments & Instrumentation
WOS类目Instruments & Instrumentation
语种英语
出版者IOP PUBLISHING LTD
WOS记录号WOS:000405067800023
URI标识http://www.irgrid.ac.cn/handle/1471x/2177296
专题高能物理研究所
通讯作者Sirunyan, A. M.
作者单位1.Yerevan Phys Inst, Yerevan, Armenia
2.Inst Hochenergiephys, Vienna, Austria
3.Inst Nucl Problems, Minsk, Byelarus
4.Natl Ctr Particle & High Energy Phys, Minsk, Byelarus
5.Univ Antwerp, Antwerp, Belgium
6.Vrije Univ Brussel, Brussels, Belgium
7.Univ Libre Bruxelles, Brussels, Belgium
8.Univ Ghent, Ghent, Belgium
9.Catholic Univ Louvain, Louvain La Neuve, Belgium
10.Univ Mons, Mons, Belgium
推荐引用方式
GB/T 7714
Sirunyan, A. M.,Tumasyan, A.,Adam, W.,et al. Mechanical stability of the cms strip tracker measured with a laser alignment system[J]. Journal of instrumentation,2017,12:39.
APA Sirunyan, A. M..,Tumasyan, A..,Adam, W..,Asilar, E..,Bergauer, T..,...&Hwang, C..(2017).Mechanical stability of the cms strip tracker measured with a laser alignment system.Journal of instrumentation,12,39.
MLA Sirunyan, A. M.,et al."Mechanical stability of the cms strip tracker measured with a laser alignment system".Journal of instrumentation 12(2017):39.

入库方式: iSwitch采集

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。