Mechanical stability of the cms strip tracker measured with a laser alignment system
文献类型:期刊论文
作者 | Sirunyan, A. M.1; Tumasyan, A.1; Adam, W.2; Asilar, E.2; Bergauer, T.2; Brandstetter, J.2; Brondolin, E.2; Dragicevic, M.2; Eroe, J.2; Flechl, M.2 |
刊名 | Journal of instrumentation |
出版日期 | 2017-04-01 |
卷号 | 12页码:39 |
ISSN号 | 1748-0221 |
关键词 | Detector alignment and calibration methods (lasers, sources, particle-beams) Large detector systems for particle and astroparticle physics Particle tracking detectors Particle tracking detectors (solid-state detectors) |
DOI | 10.1088/1748-0221/12/04/p04023 |
通讯作者 | Sirunyan, a. m.() |
英文摘要 | The cms tracker consists of 206m(2) of silicon strip sensors assembled on carbon fibre composite structures and is designed for operation in the temperature range from -25 to + 25 degrees c. the mechanical stability of tracker components during physics operation was monitored with a few mu m resolution using a dedicated laser alignment system as well as particle tracks from cosmic rays and hadron-hadron collisions. during the lhc operational period of 2011-2013 at stable temperatures, the components of the tracker were observed to experience relative movements of less than 30 mu m. in addition, temperature variations were found to cause displacements of tracker structures of about 2 mu m/degrees c, which largely revert to their initial positions when the temperature is restored to its original value. |
WOS关键词 | DETECTOR |
WOS研究方向 | Instruments & Instrumentation |
WOS类目 | Instruments & Instrumentation |
语种 | 英语 |
出版者 | IOP PUBLISHING LTD |
WOS记录号 | WOS:000405067800023 |
URI标识 | http://www.irgrid.ac.cn/handle/1471x/2177296 |
专题 | 高能物理研究所 |
通讯作者 | Sirunyan, A. M. |
作者单位 | 1.Yerevan Phys Inst, Yerevan, Armenia 2.Inst Hochenergiephys, Vienna, Austria 3.Inst Nucl Problems, Minsk, Byelarus 4.Natl Ctr Particle & High Energy Phys, Minsk, Byelarus 5.Univ Antwerp, Antwerp, Belgium 6.Vrije Univ Brussel, Brussels, Belgium 7.Univ Libre Bruxelles, Brussels, Belgium 8.Univ Ghent, Ghent, Belgium 9.Catholic Univ Louvain, Louvain La Neuve, Belgium 10.Univ Mons, Mons, Belgium |
推荐引用方式 GB/T 7714 | Sirunyan, A. M.,Tumasyan, A.,Adam, W.,et al. Mechanical stability of the cms strip tracker measured with a laser alignment system[J]. Journal of instrumentation,2017,12:39. |
APA | Sirunyan, A. M..,Tumasyan, A..,Adam, W..,Asilar, E..,Bergauer, T..,...&Hwang, C..(2017).Mechanical stability of the cms strip tracker measured with a laser alignment system.Journal of instrumentation,12,39. |
MLA | Sirunyan, A. M.,et al."Mechanical stability of the cms strip tracker measured with a laser alignment system".Journal of instrumentation 12(2017):39. |
入库方式: iSwitch采集
来源:高能物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。