Cds circuit with bla function for x-ray ccd applications
文献类型:期刊论文
作者 | Lu, Bo1,5; Chen, Yong2; Luo, Jiajun3,4; Zhou, Yumei3,4 |
刊名 | Electronics letters
![]() |
出版日期 | 2017-06-08 |
卷号 | 53期号:12页码:770-771 |
ISSN号 | 0013-5194 |
DOI | 10.1049/el.2017.0702 |
通讯作者 | Lu, bo(luboihep@outlook.com) |
英文摘要 | Correlated double sampling (cds) circuits are essential to process the x-ray charge-coupled devices (ccds) that have been used in the modern x-ray astronomical field. a novel cds circuit is presented. the innovation of the circuit is that it greatly improves the noise and linearity performances through moving the clamping switch out of the signal path as well as omitting the sampling switch which eliminates the nonlinearity and thermal noise introduced by these switches. also, a baseline adjustment (bla) circuit is incorporated so as to make efficient use of the dynamic range of the adc, making the cds circuit flexible to interface the ccd operating under a wide range of temperatures. a prototype application-specific integrated circuit (asic) is designed with globalfoundries 0.35 mu m cmos process and the experimental results show that with pixel rate varying from 100 khz to 1 mhz, the integral nonlinearity and equivalent input noise performances are quite consistent, which are better than 27 ppm and 23 mu v, respectively, within a dynamic range of 1.5 v-pp. the effective adjustment range of the bla is at least 2 v, and the power consumption for a single cds core is 10 mw approximately from a 3.3 v power supply. |
WOS研究方向 | Engineering |
WOS类目 | Engineering, Electrical & Electronic |
语种 | 英语 |
WOS记录号 | WOS:000402877400007 |
出版者 | INST ENGINEERING TECHNOLOGY-IET |
URI标识 | http://www.irgrid.ac.cn/handle/1471x/2177320 |
专题 | 高能物理研究所 |
通讯作者 | Lu, Bo |
作者单位 | 1.Univ Chinese Acad Sci, Chinese Acad Sci, Smart Sensing Ctr, Inst Microelect, Beijing, Peoples R China 2.Chinese Acad Sci, Inst High Energy Phys, Key Lab Particle Astrophys, Beijing, Peoples R China 3.Chinese Acad Sci, Key Lab Silicon Device Technol, Beijing, Peoples R China 4.Chinese Acad Sci, Smart Sensing Ctr Respectively, Inst Microelect, Beijing, Peoples R China 5.Univ Chinese Acad Sci, Chinese Acad Sci, Inst High Energy Phys, Beijing, Peoples R China |
推荐引用方式 GB/T 7714 | Lu, Bo,Chen, Yong,Luo, Jiajun,et al. Cds circuit with bla function for x-ray ccd applications[J]. Electronics letters,2017,53(12):770-771. |
APA | Lu, Bo,Chen, Yong,Luo, Jiajun,&Zhou, Yumei.(2017).Cds circuit with bla function for x-ray ccd applications.Electronics letters,53(12),770-771. |
MLA | Lu, Bo,et al."Cds circuit with bla function for x-ray ccd applications".Electronics letters 53.12(2017):770-771. |
入库方式: iSwitch采集
来源:高能物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。