Signal-to-noise ratio comparison of angular signal radiography and phase stepping method
文献类型:期刊论文
作者 | Faiz, Wali1; Zhu, Peiping2; Hu, Renfang3; Gao, Kun1; Wu, Zhao1; Bao, Yuan3; Tian, Yangchao1 |
刊名 | Chinese physics b
![]() |
出版日期 | 2017-12-01 |
卷号 | 26期号:12页码:6 |
关键词 | Angular signal radiography (asr) Phase-stepping (ps) Signal-to-noise ratio (snrs) Information retrieval method |
ISSN号 | 1674-1056 |
DOI | 10.1088/1674-1056/26/12/120601 |
通讯作者 | Zhu, peiping(zhupp@ihep.ac.cn) ; Wu, zhao(wuzhao@ustc.edu.cn) ; Tian, yangchao(ychtian@ustc.edu.cn) |
英文摘要 | Grating-based x-ray phase contrast imaging has the potential to be applied in future medical applications as it is compatible with both laboratory and synchrotron source. however, information retrieval methods are important because acquisition speed, scanning mode, image quality, and radiation dose depend on them. phase-stepping (ps) is a widely used method to retrieve information, while angular signal radiography (asr) is a newly established method. in this manuscript, signal-to-noise ratios (snrs) of asr are compared with that of ps. numerical experiments are performed to validate theoretical results. snrs comparison shows that for refraction and scattering images asr has higher snr than ps method, while for absorption image both methods have same snr. therefore, our conclusions would have guideline in future preclinical and clinical applications. |
WOS关键词 | RAY TALBOT INTERFEROMETRY ; GRATING INTERFEROMETER ; COMPUTED-TOMOGRAPHY ; RETRIEVAL |
WOS研究方向 | Physics |
WOS类目 | Physics, Multidisciplinary |
语种 | 英语 |
WOS记录号 | WOS:000417578300001 |
出版者 | IOP PUBLISHING LTD |
URI标识 | http://www.irgrid.ac.cn/handle/1471x/2178266 |
专题 | 高能物理研究所 |
通讯作者 | Zhu, Peiping; Wu, Zhao; Tian, Yangchao |
作者单位 | 1.Univ Sci & Technol China, Natl Synchrotron Radiat Lab, Hefei 230029, Anhui, Peoples R China 2.Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China 3.Shanghai United Imaging Healthcare Co Ltd, Shanghai 201807, Peoples R China |
推荐引用方式 GB/T 7714 | Faiz, Wali,Zhu, Peiping,Hu, Renfang,et al. Signal-to-noise ratio comparison of angular signal radiography and phase stepping method[J]. Chinese physics b,2017,26(12):6. |
APA | Faiz, Wali.,Zhu, Peiping.,Hu, Renfang.,Gao, Kun.,Wu, Zhao.,...&Tian, Yangchao.(2017).Signal-to-noise ratio comparison of angular signal radiography and phase stepping method.Chinese physics b,26(12),6. |
MLA | Faiz, Wali,et al."Signal-to-noise ratio comparison of angular signal radiography and phase stepping method".Chinese physics b 26.12(2017):6. |
入库方式: iSwitch采集
来源:高能物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。