中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Signal-to-noise ratio comparison of angular signal radiography and phase stepping method

文献类型:期刊论文

作者Faiz, Wali1; Zhu, Peiping2; Hu, Renfang3; Gao, Kun1; Wu, Zhao1; Bao, Yuan3; Tian, Yangchao1
刊名Chinese physics b
出版日期2017-12-01
卷号26期号:12页码:6
关键词Angular signal radiography (asr) Phase-stepping (ps) Signal-to-noise ratio (snrs) Information retrieval method
ISSN号1674-1056
DOI10.1088/1674-1056/26/12/120601
通讯作者Zhu, peiping(zhupp@ihep.ac.cn) ; Wu, zhao(wuzhao@ustc.edu.cn) ; Tian, yangchao(ychtian@ustc.edu.cn)
英文摘要Grating-based x-ray phase contrast imaging has the potential to be applied in future medical applications as it is compatible with both laboratory and synchrotron source. however, information retrieval methods are important because acquisition speed, scanning mode, image quality, and radiation dose depend on them. phase-stepping (ps) is a widely used method to retrieve information, while angular signal radiography (asr) is a newly established method. in this manuscript, signal-to-noise ratios (snrs) of asr are compared with that of ps. numerical experiments are performed to validate theoretical results. snrs comparison shows that for refraction and scattering images asr has higher snr than ps method, while for absorption image both methods have same snr. therefore, our conclusions would have guideline in future preclinical and clinical applications.
WOS关键词RAY TALBOT INTERFEROMETRY ; GRATING INTERFEROMETER ; COMPUTED-TOMOGRAPHY ; RETRIEVAL
WOS研究方向Physics
WOS类目Physics, Multidisciplinary
语种英语
WOS记录号WOS:000417578300001
出版者IOP PUBLISHING LTD
URI标识http://www.irgrid.ac.cn/handle/1471x/2178266
专题高能物理研究所
通讯作者Zhu, Peiping; Wu, Zhao; Tian, Yangchao
作者单位1.Univ Sci & Technol China, Natl Synchrotron Radiat Lab, Hefei 230029, Anhui, Peoples R China
2.Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
3.Shanghai United Imaging Healthcare Co Ltd, Shanghai 201807, Peoples R China
推荐引用方式
GB/T 7714
Faiz, Wali,Zhu, Peiping,Hu, Renfang,et al. Signal-to-noise ratio comparison of angular signal radiography and phase stepping method[J]. Chinese physics b,2017,26(12):6.
APA Faiz, Wali.,Zhu, Peiping.,Hu, Renfang.,Gao, Kun.,Wu, Zhao.,...&Tian, Yangchao.(2017).Signal-to-noise ratio comparison of angular signal radiography and phase stepping method.Chinese physics b,26(12),6.
MLA Faiz, Wali,et al."Signal-to-noise ratio comparison of angular signal radiography and phase stepping method".Chinese physics b 26.12(2017):6.

入库方式: iSwitch采集

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。