Relative validity of an indirect calorimetry device for measuring resting energy expenditure and respiratory quotient

文献类型:期刊论文

作者Wang, Xi1,2; Wang, Yuan1; Ding, Zenghui1,2; Cao, Guangbei1; Hu, Fusong1,2; Sun, Yining1; Ma, Zuchang1; Zhou, Duoqi3; Su, Benyue3
刊名ASIA PACIFIC JOURNAL OF CLINICAL NUTRITION
出版日期2018
卷号27期号:1页码:72-77
关键词indirect calorimetry resting energy expenditure respiratory quotient oxygen consumption validation
ISSN号0964-7058
DOI10.6133/apjcn.032017.02
英文摘要

Background and Objectives: Resting energy expenditure (REE) and respiratory quotient (RQ) are important for optimal nutritional care. The purpose of this study was to assess the accuracy and repeatability of an indirect calorimetry device (IIM-IC-100) in the measurement of REE and RQ in healthy Chinese adults. Methods and Study Design: A total of 38 healthy adults (19 male and 19 female) aged 18-52 years (25 +/- 6 years) were enrolled in this study. REE and RQ were measured by IIM-IC-100 and by VO2000, alternately and in duplicate. Results: There was a highly significant correlation between IIM-IC-100 REE and VO2000 REE (r=0.906, p<0.001), with mean IIM-IC-100 REE significantly higher than that of VO2000 (1475 +/- 269 vs 1394 +/- 313 kcal/d, p=0.002). Bland-Altman analysis revealed that the mean difference between IIM-IC-100 REE and VO2000 REE was 81.3 kcal/d, with limits of agreement of -185 to + 347 kcal/d. There was no significant difference in RQ between the two devices. No significant differences were observed between the repeated measurements for both devices. Intra-subject coefficients of variation (CVs) of REE were smaller for IIM-IC-100 (5.8%) than for VO2000 (10.5%), while CVs of RQ were similar for IIM-IC-100 (7.2%) and VO2000 (6.9%). Conclusions: These preliminary data indicated that the IIM-IC-100 showed promise as an accurate and precise tool in the assessment of REE and RQ in healthy Chinese adults.

WOS关键词BODY-MASS INDEX ; METABOLIC-RATE ; CLINICAL VALIDATION ; VENTILATED CANOPY ; CHINESE ADULTS ; GAS-EXCHANGE ; FACE MASK ; OBESITY ; WOMEN ; RELIABILITY
资助项目Science and Technology Service Network Initiative[KFJ-SW-STS-161] ; Major projects of science and technology in Anhui Province[15czz02019] ; National Natural Science Foundation of China[61603371]
WOS研究方向Nutrition & Dietetics
语种英语
WOS记录号WOS:000419140900006
出版者H E C PRESS, HEALTHY EATING CLUB PTY LTD
源URL[http://ir.hfcas.ac.cn:8080/handle/334002/35006]  
专题合肥物质科学研究院_中科院合肥智能机械研究所
通讯作者Ma, Zuchang
作者单位1.Chinese Acad Sci, Inst Intelligent Machines, Res Ctr Informat Technol Sports & Hlth, Hefei 230031, Anhui, Peoples R China
2.Univ Sci & Technol China, Dept Automat, Hefei, Anhui, Peoples R China
3.Anqing Normal Univ, Sch Phys Educ, Anqing, Anhui, Peoples R China
推荐引用方式
GB/T 7714
Wang, Xi,Wang, Yuan,Ding, Zenghui,et al. Relative validity of an indirect calorimetry device for measuring resting energy expenditure and respiratory quotient[J]. ASIA PACIFIC JOURNAL OF CLINICAL NUTRITION,2018,27(1):72-77.
APA Wang, Xi.,Wang, Yuan.,Ding, Zenghui.,Cao, Guangbei.,Hu, Fusong.,...&Su, Benyue.(2018).Relative validity of an indirect calorimetry device for measuring resting energy expenditure and respiratory quotient.ASIA PACIFIC JOURNAL OF CLINICAL NUTRITION,27(1),72-77.
MLA Wang, Xi,et al."Relative validity of an indirect calorimetry device for measuring resting energy expenditure and respiratory quotient".ASIA PACIFIC JOURNAL OF CLINICAL NUTRITION 27.1(2018):72-77.

入库方式: OAI收割

来源:合肥物质科学研究院

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。