Effects of the generator and evaporator temperature differences on a double absorption heat transformer-Different control strategies on utilizing heat sources

文献类型:期刊论文

作者Wang, Hanzhi1,2,3,4; Li, Huashan1,2,3; Bu, Xianbiao1,2,3; Wang, Lingbao1,2,3,4
刊名ENERGY CONVERSION AND MANAGEMENT
出版日期2017-04-15
卷号138页码:12-21
关键词Exergy Destruction Rate Double Absorption Heat Transformer Generator Temperature Evaporator Temperature Heat Source Temperature Control Strategies
DOI10.1016/j.enconman.2017.01.076
文献子类Article
英文摘要The combination of the absorption heat transformer with renewable energy systems, like solar thermal systems, is raising more and more concern. In those combined systems the strategies on utilizing heat sources can affect system thermodynamic performance significantly. Therefore, this study presents a detailed analysis on the effect of the heat source temperature and different heat source flow patterns on the performance of a double absorption heat transformer (DAHT). A detailed comparative study is carried out to clarify the impact of the generator and evaporator temperature differences (GETD) on the coefficient of performance (COP), exergy efficient (ECOP), exergy destruction rates in the individual components and heat transfer areas needed for each component. The results show that the generator, condenser and absorber-evaporator are responsible for most of the exergy destruction rate in the DAHT system; the parallel-flow configuration (the generator temperature is equal to the evaporator temperature) performs better under the high gross temperature lift conditions; in the case of the counter flow configuration (the generator temperature is relatively higher), better performance can be obtained in both the COP and ECOP under the proper heat source temperature (85 and 95 degrees C); the fair-flow configuration (higher temperature in the evaporator) is not recommended in this paper due to no advantages found in either thermodynamic performance or system size. (C) 2017 Elsevier Ltd. All rights reserved.
WOS关键词FLAT-PLATE COLLECTOR ; EXERGY ANALYSIS ; SINGLE-STAGE ; THERMODYNAMIC PERFORMANCE ; WATER/LITHIUM BROMIDE ; WORKING FLUID ; SYSTEM ; ENERGY ; WATER ; OPTIMIZATION
语种英语
WOS记录号WOS:000396948700002
资助机构Science and Technology Planning Project of Guangdong Province(20138010405013) ; Pearl River S&T Nova Program of Guangzhou(2014J2200079) ; Key Laboratory of Renewable Energy, Chinese Academy of Sciences(y507j71001) ; Youth Innovation Promotion Association, Chinese Academy of Sciences(2017402)
源URL[http://ir.giec.ac.cn/handle/344007/14102]  
专题中国科学院广州能源研究所
作者单位1.Chinese Acad Sci, Guangzhou Inst Energy Convers, Guangzhou 510640, Guangdong, Peoples R China
2.CAS Key Lab Renewable Energy, Guangzhou 510640, Guangdong, Peoples R China
3.Guangdong Prov Key Lab New & Renewable Energy Res, Guangzhou 510640, Guangdong, Peoples R China
4.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Wang, Hanzhi,Li, Huashan,Bu, Xianbiao,et al. Effects of the generator and evaporator temperature differences on a double absorption heat transformer-Different control strategies on utilizing heat sources[J]. ENERGY CONVERSION AND MANAGEMENT,2017,138:12-21.
APA Wang, Hanzhi,Li, Huashan,Bu, Xianbiao,&Wang, Lingbao.(2017).Effects of the generator and evaporator temperature differences on a double absorption heat transformer-Different control strategies on utilizing heat sources.ENERGY CONVERSION AND MANAGEMENT,138,12-21.
MLA Wang, Hanzhi,et al."Effects of the generator and evaporator temperature differences on a double absorption heat transformer-Different control strategies on utilizing heat sources".ENERGY CONVERSION AND MANAGEMENT 138(2017):12-21.

入库方式: OAI收割

来源:广州能源研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。