中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Corner Detection Based Automatic Segmentation of Bioresorbable Vascular Scaffold Struts in IVOCT Images

文献类型:会议论文

作者Qin, Xianjing1; Yao, Linlin2; Jin, Qinhua3; Jing, Jing3; Chen, Yundai3; Cao, Yihui2; Li, Jianan2; Zhu, Rui2
出版日期2018-10-26
会议日期2018-07-18
会议地点Honolulu, HI, United states
卷号2018-July
DOI10.1109/EMBC.2018.8512440
页码604-607
英文摘要

Bioresorbable Vascular scaffold (BVS) is a promising type of stent in percutaneous coronary intervention. Struts apposition assessment is important to ensure the safety of implanted BVS. Currently, BVS struts apposition analysis in IVOCT images still depends on manual delineation of struts, which is labor intensive and time consuming. Automatic struts segmentation is highly desired to simplify and speed up quantitative analysis. However, it is difficult to segment struts accurately based on the contour, due to the influence of fractures inside strut and blood artifacts around strut. In this paper, a novel framework of automatic struts segmentation based on four corners is introduced, in which priori knowledge is utilized that struts have obvious feature of box-shape. Firstly, a cascaded AdaBoost classifier based on enriched haar-like features is trained to detect struts corners. Then, segmentation result can be obtained based on the four detected corners of each strut. Tested on five pullbacks consisting of 483 images with strut, our novel method achieved an average Dice's coefficient of 0.82 for strut segmentation areas. It concludes that our method can segment struts accurately and robustly. Furthermore, automatic struts malapposition analysis in clinical practice is feasible based on the segmentation results. © 2018 IEEE.

产权排序2
会议录40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2018
会议录出版者Institute of Electrical and Electronics Engineers Inc.
语种英语
ISSN号1557170X
ISBN号9781538636466
源URL[http://ir.opt.ac.cn/handle/181661/31110]  
专题西安光学精密机械研究所_瞬态光学技术国家重点实验室
作者单位1.Department of Aerospace Biodynamics, Fourth Military Medical University, Xi'an, Shaanxi; 710032, China;
2.Laboratory of Transient Optics and Photonics, Xi'An Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an, Shaanxi; 710119, China;
3.Department of Cardiology, Chinese PLA General Hospital, Beijing, China
推荐引用方式
GB/T 7714
Qin, Xianjing,Yao, Linlin,Jin, Qinhua,et al. Corner Detection Based Automatic Segmentation of Bioresorbable Vascular Scaffold Struts in IVOCT Images[C]. 见:. Honolulu, HI, United states. 2018-07-18.

入库方式: OAI收割

来源:西安光学精密机械研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。