中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Three Dimensional Hessian matrix based quantitative vascular imaging of rat iris with optical-resolution photoacoustic microscopy

文献类型:期刊论文

作者Huangxuan Zhao;  Guangsong Wang;  Wenjia Wang;  Kunya Zhang; Xiuqing Qian;  Haixia Zhang;  Lin Li;  Zhicheng Liu;  Chengbo Liu;  Riqiang Lin
刊名Journal of Biomedical Optics
出版日期2018
文献子类期刊论文
英文摘要For the diagnosis and evaluation of ophthalmic diseases, imaging and quantitative characterization of vasculature in the iris are very important. The recently developed photoacoustic imaging, which is ultrasensitive in imaging endogenous hemoglobin molecules, provides a highly efficient label-free method for imaging blood vasculature in the iris. However, the development of advanced vascular quantification algorithms is still needed to enable accurate characterization of the underlying vasculature. We have developed a vascular information quantification algorithm by adopting a three-dimensional (3-D) Hessian matrix and applied for processing iris vasculature images obtained with a custom-built optical-resolution photoacoustic imaging system (OR-PAM). For the first time, we demonstrate in vivo 3-D vascular structures of a rat iris with a the label-free imaging method and also accurately extract quantitative vascular information, such as vessel diameter, vascular density, and vascular tortuosity. Our results indicate that the developed algorithm is capable of quantifying the vasculature in the 3-D photoacoustic images of the iris in-vivo, thus enhancing the diagnostic capability of the OR-PAM system for vascular-related ophthalmic diseases in vivo.
URL标识查看原文
语种英语
源URL[http://ir.siat.ac.cn:8080/handle/172644/14215]  
专题深圳先进技术研究院_医工所
推荐引用方式
GB/T 7714
Huangxuan Zhao, Guangsong Wang, Wenjia Wang,et al. Three Dimensional Hessian matrix based quantitative vascular imaging of rat iris with optical-resolution photoacoustic microscopy[J]. Journal of Biomedical Optics,2018.
APA Huangxuan Zhao., Guangsong Wang., Wenjia Wang., Kunya Zhang.,Xiuqing Qian.,...& Tan Li.(2018).Three Dimensional Hessian matrix based quantitative vascular imaging of rat iris with optical-resolution photoacoustic microscopy.Journal of Biomedical Optics.
MLA Huangxuan Zhao,et al."Three Dimensional Hessian matrix based quantitative vascular imaging of rat iris with optical-resolution photoacoustic microscopy".Journal of Biomedical Optics (2018).

入库方式: OAI收割

来源:深圳先进技术研究院

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。