中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Rotator Cuff Tendon Assessment Using Magic-Angle Insensitive 3D Ultrashort Echo Time Cones Magnetization Transfer (UTE-Cones-MT) Imaging and Modeling With Histological Correlation

文献类型:期刊论文

作者Jonathan H. Wong; Yanchun Zhu; Xin Cheng; Yajun Ma; Yaoqin Xie; Jiang Du; Eric Y. Chang
刊名JOURNAL OF MAGNETIC RESONANCE IMAGING
出版日期2018
文献子类期刊论文
英文摘要Background Rotator cuff tendons (RCTs) are challenging to image due to the “magic angle effect” and their short T2. Purpose To assess the degree of magic angle sensitivity of human RCTs and to utilize a 3D ultrashort echo time Cones sequence with magnetization transfer preparation (UTE-Cones-MT) and two-pool quantitative MT modeling with histological correlation. We hypothesized that MT parameters would be less sensitive to the magic angle compared with conventional T2 measurements. Study Type Prospective imaging pathologic correlation. Specimen Twenty cadaveric rotator cuff tendons were imaged at five sample orientations ranging from 0–90° relative to the B0 field. Field Strength/Sequence 3T/3D UTE-Cones-MT and Carr–Purcell–Meiboom–Gill (CPMG). Assessment Two-pool quantitative MT modeling parameters and T2 values were calculated in regions of interest drawn by a medical physicist. Histopathological analysis was performed and mild and severe tendinopathy groups were assigned by a histopathologist and histotechnician. Statistical Tests Coefficients of variations (CVs) were calculated for measures between the different orientations and group means were compared for each measure. Results CVs of T2 and macromolecular fractions between orientations were 26.14 ± 16.82% and 6.18 ± 2.77% (mean ± SD), respectively. T2 measurements at 0°, 27°, 70°, and 90° showed significant differences between the two histological groups (P = 0.004, 0.008, 0.003, and 0.015, respectively), but not at 55° (P = 0.611). Mean T2 value ranges between orientations for the mild and severe tendinopathy groups were 15.27–30.32 msec and 20.81–35.85 msec, respectively, showing overlap despite statistically significant differences (P = 0.003). Macromolecular fractions at all angles showed significant differences between the two groups (P < 0.0001). Mean fraction ranges between orientations for the mild and severe tendinopathy groups were 14.32–17.17% and 10.00–13.75% respectively (P < 0.0001) with no overlap. Data Conclusion Compared with T2, macromolecular fraction obtained with the 3D UTE-Cones-MT technique is resistant to the magic angle effect and is more sensitive to RCT degeneration.
URL标识查看原文
语种英语
源URL[http://ir.siat.ac.cn:8080/handle/172644/14232]  
专题深圳先进技术研究院_医工所
推荐引用方式
GB/T 7714
Jonathan H. Wong,Yanchun Zhu,Xin Cheng,et al. Rotator Cuff Tendon Assessment Using Magic-Angle Insensitive 3D Ultrashort Echo Time Cones Magnetization Transfer (UTE-Cones-MT) Imaging and Modeling With Histological Correlation[J]. JOURNAL OF MAGNETIC RESONANCE IMAGING,2018.
APA Jonathan H. Wong.,Yanchun Zhu.,Xin Cheng.,Yajun Ma.,Yaoqin Xie.,...&Eric Y. Chang.(2018).Rotator Cuff Tendon Assessment Using Magic-Angle Insensitive 3D Ultrashort Echo Time Cones Magnetization Transfer (UTE-Cones-MT) Imaging and Modeling With Histological Correlation.JOURNAL OF MAGNETIC RESONANCE IMAGING.
MLA Jonathan H. Wong,et al."Rotator Cuff Tendon Assessment Using Magic-Angle Insensitive 3D Ultrashort Echo Time Cones Magnetization Transfer (UTE-Cones-MT) Imaging and Modeling With Histological Correlation".JOURNAL OF MAGNETIC RESONANCE IMAGING (2018).

入库方式: OAI收割

来源:深圳先进技术研究院

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。