Towards Characterization and Adaptive Compensation of Backlash in a Novel Robotic Catheter System for Cardiovascular Interventions
文献类型:期刊论文
| 作者 | Guo Shuai Wang; Hui Li; Lei Wang; Olatunji Mumini Omisore; Shi Peng Han; Ling Xue Ren; Fang Liang Ou |
| 刊名 | IEEE Transactions on Biomedical Circuits and Systems
![]() |
| 出版日期 | 2018 |
| 文献子类 | 期刊论文 |
| 英文摘要 | —Despite the success and prospects of the robotic catheter system for the cardiovascular access, loss of vision, and haptics have limited its global adoption. A direct implication is the great difficulty posed when trying to eliminate the backlash in catheters during vascular cannulations. As a result, physicians and patients end up been exposed to high radiation for a long period of time. Existing control systems proposed for such interventional robots have not fully consider the hysteretic (backlash) behavior. In this study, a novel robotic catheter system is designed for accessing the human cardiac area through the radial vasculature, while single factor descriptive analysis is employed to characterize the backlash behavior during axial motions of the interventional robot. Based on the descriptive analysis, an adaptive system is proposed for the backlash compensation during the cardiovascular access. The adaptive system consists of a neuro-fuzzy module that predicts a backlash gap based on bounded motion signals, and contact force modulated from a modified error-based force control model. The proposed system is implemented in MATLAB and visual C++. Finally, an in vitro experiment with a human tubular model, shows that the proposed adaptive compensation system can minimize the backlash occurrence during cardiovascular access. |
| URL标识 | 查看原文 |
| 语种 | 英语 |
| 源URL | [http://ir.siat.ac.cn:8080/handle/172644/14244] ![]() |
| 专题 | 深圳先进技术研究院_医工所 |
| 推荐引用方式 GB/T 7714 | Guo Shuai Wang,Hui Li,Lei Wang,et al. Towards Characterization and Adaptive Compensation of Backlash in a Novel Robotic Catheter System for Cardiovascular Interventions[J]. IEEE Transactions on Biomedical Circuits and Systems,2018. |
| APA | Guo Shuai Wang.,Hui Li.,Lei Wang.,Olatunji Mumini Omisore.,Shi Peng Han.,...&Fang Liang Ou.(2018).Towards Characterization and Adaptive Compensation of Backlash in a Novel Robotic Catheter System for Cardiovascular Interventions.IEEE Transactions on Biomedical Circuits and Systems. |
| MLA | Guo Shuai Wang,et al."Towards Characterization and Adaptive Compensation of Backlash in a Novel Robotic Catheter System for Cardiovascular Interventions".IEEE Transactions on Biomedical Circuits and Systems (2018). |
入库方式: OAI收割
来源:深圳先进技术研究院
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。

