英文摘要Purpose: The purpose of this study is to evaluate the effect of diffusion on SSFP (Steady-state Free Precession) signals in triple-echo steady state (TESS) sequence and ultimately on the accuracy of T2 relaxometry. Methods: The extended phase graph (EPG) algorithm was used to study the effect of diffusion on SSFP signals and T2 relaxometry. The simulation results were verified by a commercial phantom and in vivo studies. Based on the simulation results, a correction scheme was proposed to correct the estimated T2 values. Results: T2 underestimation in TESS was evident in case of small flip angle and large unbalanced gradient moment on objects with large T2 and D values. The T2 underestimation mainly originated from the diffusion sensitivity of SSFP-echo. It was also observed that SSFP-FID (Free Induction Decay) signals increased with increasing diffusion weighting under some specific conditions. The proposed correction scheme corrected the T2 underestimation, which verified that the underestimation was due to the neglect of diffusion effect. For clinical practice of TESS in tissues with short T2 such as cartilage and muscle, the diffusion effect of TESS is negligible. Conclusion: The effect of diffusion cannot be neglected during TESS T2 quantification as it is the main source of T2 underestimation when small flip angle and large unbalanced gradient moment is used, especially for objects with large T2 and D values. (C) 2018 Elsevier Inc. All rights reserved.
URL标识查看原文
语种英语
源URL[http://ir.siat.ac.cn:8080/handle/172644/14333]  
专题深圳先进技术研究院_医工所
推荐引用方式
GB/T 7714
Cheng, Chuanli,Tie, Changjun,Liu, Xin,et al. Diffusion effect on T2 relaxometry in triple-echo steady state free precession sequence[J]. JOURNAL OF MAGNETIC RESONANCE,2018.
APA Cheng, Chuanli.,Tie, Changjun.,Liu, Xin.,Liang, Dong.,Zheng, Hairong.,...&Wan, Qian.(2018).Diffusion effect on T2 relaxometry in triple-echo steady state free precession sequence.JOURNAL OF MAGNETIC RESONANCE.
MLA Cheng, Chuanli,et al."Diffusion effect on T2 relaxometry in triple-echo steady state free precession sequence".JOURNAL OF MAGNETIC RESONANCE (2018).

入库方式: OAI收割

来源:深圳先进技术研究院

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。