中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Synergistic effect of enhanced low-dose-rate sensitivity and single event transient in bipolar voltage comparator LM139

文献类型:期刊论文

作者Yao, S (Yao, Shuai)[ 1,2,3 ]; Lu, W (Lu, Wu)[ 1,2,4 ]; Yu, X (Yu, Xin)[ 1,2 ]; Wang, X (Wang, Xin)[ 1,2 ]; Li, XL (Li, Xiaolong)[ 1,2,3 ]; Liu, MH (Liu, Mohan)[ 1,2,3 ]; Sun, J (Sun, Jing)[ 1,2 ]; Wei, XY (Wei, XinYu)[ 1,2 ]; Chang, YD (Chang, YaoDong)[ 1,2 ]; Guo, Q (Guo, Qi)[ 1,2 ]
刊名JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY
出版日期2019
卷号56期号:2页码:172-178
关键词Enhanced low dose rate sensitivity single event transient bipolar voltage comparator synergistic effect
ISSN号0022-3131
DOI10.1080/00223131.2018.1539352
英文摘要

The bipolar voltage comparator LM139 were exposed to ionizing radiation with a high-dose-rate of 10 rad(Si)/s and a low-dose-rate of 0.01 rad(Si)/s; then, pulsed laser single-event-transient (SET) testing was performed. The experimental results show that the SET phenomenon of LM139 after low-dose-rate irradiation of 0.01 rad(Si)/s is obviously different from the SET phenomenon of LM139 after high-dose-rate irradiation of 10 rad(Si)/s. After irradiation with the low-dose-rate, the comparator LM139 has Enhanced Low Dose Rate Sensitivity (ELDRS) in terms of the total dose effect, and the SET was further influenced by ELDRS. The greater gain degradation of the internal transistor in LM139 with low-dose-rate irradiation is the direct cause of this phenomenon.

WOS记录号WOS:000455488700004
源URL[http://ir.xjipc.cas.cn/handle/365002/5666]  
专题新疆理化技术研究所_中国科学院特殊环境功能材料与器件重点试验室
通讯作者Lu, W (Lu, Wu)[ 1,2,4 ]
作者单位1.Chinese Acad Sci, Key Lab Funct Mat & Devices Special Environm, Urumqi, Peoples R China
2.Chinese Acad Sci, Xinjiang Tech Inst Phys & Chem, Urumqi, Peoples R China
3.Univ Chinese Acad Sci, Beijing, Peoples R China
4.Chinese Acad Sci, Xinjiang Tech Inst Phys & Chem, Urumqi 830011, Peoples R China
推荐引用方式
GB/T 7714
Yao, S ,Lu, W ,Yu, X ,et al. Synergistic effect of enhanced low-dose-rate sensitivity and single event transient in bipolar voltage comparator LM139[J]. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY,2019,56(2):172-178.
APA Yao, S .,Lu, W .,Yu, X .,Wang, X .,Li, XL .,...&He, CF .(2019).Synergistic effect of enhanced low-dose-rate sensitivity and single event transient in bipolar voltage comparator LM139.JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY,56(2),172-178.
MLA Yao, S ,et al."Synergistic effect of enhanced low-dose-rate sensitivity and single event transient in bipolar voltage comparator LM139".JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY 56.2(2019):172-178.