Fabricating and testing of the trim plate for the Zwicky Transient Facility

文献类型:会议论文

作者Chen Xu1,2; Yi Zheng1,2; Bo Li1,2; Xinnan Li1,2; Zhe Chen1,2; Kunxing Chen1,2; Bin Liang1,2
出版日期2018-07-10
会议名称SPIE Advances in Optical and Mechanical Technologies for Telescopes and Instrumentation III(Vol. 10706)
会议日期2018-6-10
会议地点Austin, Texas, United States
关键词ZTF Schmidt corrector Null test alignment
英文摘要
The Zwicky Transient Facility (ZTF) is a new time-domain survey project that will use a new camera with a 47 square degree field of view mounted on the Samuel Oschin 48-inch Schmidt telescope. To achieve good image quality over all sixteen 6K*6K CCDs (386mm*395mm corner to corner), a trim plate was added in front of the existing cemented achromatic doublet to form an air-spaced triplet corrector.

The trim plate is a Schmidt corrector using fused silica with 1348mm in diameter but only 15mm in thickness. The plate has been completed at NIAOT and already been mounted to
the ZTF, the PSF seems very good.

The detailed fabrication process and testing to the trim plate from fine grinding to finish are presented in this paper,which includes CMM test, NULL test design, and Computer Controlled Polishing process developed at NIAOT.
会议录Advances in Optical and Mechanical Technologies for Telescopes and Instrumentation III
学科主题天文技术与方法
语种英语
源URL[http://ir.niaot.ac.cn/handle/114a32/1547]  
专题会议论文
作者单位1.南京天文光学技术研究所
2.天文光学技术重点实验室
推荐引用方式
GB/T 7714
Chen Xu,Yi Zheng,Bo Li,et al. Fabricating and testing of the trim plate for the Zwicky Transient Facility[C]. 见:SPIE Advances in Optical and Mechanical Technologies for Telescopes and Instrumentation III(Vol. 10706). Austin, Texas, United States. 2018-6-10.

入库方式: OAI收割

来源:南京天文光学技术研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。