中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Determination of tetrodotoxin by liquid chromatography coupled with electrospray ion-trap mass spectrometry

文献类型:期刊论文

作者Li Ai-Feng; Yu Ren-Cheng; Zhou Ming-Jiang
刊名CHINESE JOURNAL OF ANALYTICAL CHEMISTRY
出版日期2007-03-01
卷号35期号:3页码:397-400
关键词Liquid Chromatography With Electrospray Ion-tap Mass Spectrometry Tetrodotoxin Selected Ion Monitoring Selected Reaction Monitoring
ISSN号0253-3820
文献子类Article
英文摘要Two methods for tetrodotoxin analysis using liquid chromatography coupled with electrospray iontrap mass spectrometry (LC-ESI-MS) have been established with C,, reversed phase column and hydrophilic interaction liquid chromatography (HILIC) column, respectively. Sensitivity and reproducibility of the methods were compared. The method using C-18 column in selected ion monitoring (SIM) mode had a detection limit (S/N = 3) of 120 pg, and a good linearity of the calibration curve was obtained for tetrodotoxin (r = 0. 9992). High reproducibility of the method was observed, with a relative standard deviation (RSD) below 10%. The method using HILIC column in SIM mode and selected reaction monitoring (SRM) mode had detection limits (S/N = 3) of 15 and 3.75 pg, respectively. Good linearity of the calibration curves was obtained for tetrodotoxin (r = 0. 9996 and 0. 9998 in SIM and SRM mode, respectively). T he reproducibility was high in SIM mode but relatively poor in SRM mode. Based on the results, the method using HILIC column in SIM mode was suggested for the analysis of tetrodotoxin with LC-MS system.; Two methods for tetrodotoxin analysis using liquid chromatography coupled with electrospray iontrap mass spectrometry (LC-ESI-MS) have been established with C,, reversed phase column and hydrophilic interaction liquid chromatography (HILIC) column, respectively. Sensitivity and reproducibility of the methods were compared. The method using C-18 column in selected ion monitoring (SIM) mode had a detection limit (S/N = 3) of 120 pg, and a good linearity of the calibration curve was obtained for tetrodotoxin (r = 0. 9992). High reproducibility of the method was observed, with a relative standard deviation (RSD) below 10%. The method using HILIC column in SIM mode and selected reaction monitoring (SRM) mode had detection limits (S/N = 3) of 15 and 3.75 pg, respectively. Good linearity of the calibration curves was obtained for tetrodotoxin (r = 0. 9996 and 0. 9998 in SIM and SRM mode, respectively). T he reproducibility was high in SIM mode but relatively poor in SRM mode. Based on the results, the method using HILIC column in SIM mode was suggested for the analysis of tetrodotoxin with LC-MS system.
语种英语
WOS记录号WOS:000245735200018
公开日期2010-12-30
源URL[http://ir.qdio.ac.cn/handle/337002/6261]  
专题海洋研究所_海洋生态与环境科学重点实验室
作者单位1.Ocean Univ China, Key Lab Marine Environm Sci & Ecol, Qingdao 266100, Peoples R China
2.Chinese Acad Sci, Inst Oceanol, Key Lab Marine Ecol & Environm Sci, Qingdao 266071, Peoples R China
推荐引用方式
GB/T 7714
Li Ai-Feng,Yu Ren-Cheng,Zhou Ming-Jiang. Determination of tetrodotoxin by liquid chromatography coupled with electrospray ion-trap mass spectrometry[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2007,35(3):397-400.
APA Li Ai-Feng,Yu Ren-Cheng,&Zhou Ming-Jiang.(2007).Determination of tetrodotoxin by liquid chromatography coupled with electrospray ion-trap mass spectrometry.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,35(3),397-400.
MLA Li Ai-Feng,et al."Determination of tetrodotoxin by liquid chromatography coupled with electrospray ion-trap mass spectrometry".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 35.3(2007):397-400.

入库方式: OAI收割

来源:海洋研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。