Computational study of film cooling and flowfields on a stepped vane endwall with a row of cylindrical hole and interrupted slot injections
文献类型:期刊论文
作者 | Xu Qingzong; Du Qiang; Wang Pei; Zhu Junqiang |
刊名 | International journal of heat and mass transfer |
出版日期 | 2019-05-01 |
卷号 | 134页码:796-806 |
ISSN号 | 0017-9310 |
关键词 | Stepped endwall Film cooling Interrupted slot Blowing ratio |
DOI | 10.1016/j.ijheatmasstransfer.2019.01.093 |
通讯作者 | Du qiang(duqiang@iet.cn) |
英文摘要 | Endwall is one of the critical regions to perform film cooling for gas turbine because of not only the increase of turbine inlet temperature but also the complicated secondary flow. typical endwall film cooling configuration includes leakage slot at combustor-vane interface and discrete cooling holes on the wall. this paper mainly studied the effect of endwall step on the cooling performance of downstream cooling holes. the combustor-turbine interface in this paper is a kind of backward-facing step, causing an interrupted slot. the detailed characteristic of the interrupted slot has been investigated in the previous study. three dimensional reynolds-averaged navier-stokes equations with shear stress turbulence model (sst) k-omega was solved to perform the calculations of endwall film effectiveness. the adiabatic film effectiveness on the flat endwall was compared with that on the stepped endwall with and without the interrupted slot. results showed a significant impact of the endwall step on the adiabatic film cooling effectiveness. coolant jet downstream of the step is split into two parts due to the effects of step vortex (sv) and cross flow. detailed flowfields in spanwise, pitchwise and axial planes explain the formation and development of secondary flow near the cooling holes. for a range of blowing ratio from 0.6 to 1.2, increasing the blowing ratio of cooling holes deteriorates the adiabatic film cooling effectiveness upstream and downstream of the cooling holes due to the jet liftoff. it is found that cooling effectiveness is strongly dependent on the axial position of the hole. placing the cooling holes downstream at leading edge plane of the cascade little effect of the step vortex on the film effectiveness and, subsequently, relatively uniform coolant coverage was observed on the endwall. (c) 2019 elsevier ltd. all rights reserved. |
WOS关键词 | SECONDARY-FLOW ; TURBINE ENDWALL ; PREDICTIONS ; LOSSES ; DESIGN ; FILLET |
WOS研究方向 | Thermodynamics ; Engineering ; Mechanics |
WOS类目 | Thermodynamics ; Engineering, Mechanical ; Mechanics |
语种 | 英语 |
出版者 | PERGAMON-ELSEVIER SCIENCE LTD |
WOS记录号 | WOS:000462418300068 |
URI标识 | http://www.irgrid.ac.cn/handle/1471x/2373501 |
专题 | 工程热物理研究所 |
通讯作者 | Du Qiang |
作者单位 | Univ Chinese Acad Sci, Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China |
推荐引用方式 GB/T 7714 | Xu Qingzong,Du Qiang,Wang Pei,et al. Computational study of film cooling and flowfields on a stepped vane endwall with a row of cylindrical hole and interrupted slot injections[J]. International journal of heat and mass transfer,2019,134:796-806. |
APA | Xu Qingzong,Du Qiang,Wang Pei,&Zhu Junqiang.(2019).Computational study of film cooling and flowfields on a stepped vane endwall with a row of cylindrical hole and interrupted slot injections.International journal of heat and mass transfer,134,796-806. |
MLA | Xu Qingzong,et al."Computational study of film cooling and flowfields on a stepped vane endwall with a row of cylindrical hole and interrupted slot injections".International journal of heat and mass transfer 134(2019):796-806. |
入库方式: iSwitch采集
来源:工程热物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。