Determination of the detection limit for a noncollinear optical parametric amplification-gated femtosecond time-resolved fluorescence spectrometer - reply to the comment on "ultrasensitive femtosecond time-resolved fluorescence spectroscopy for relaxation processes by using parametric amplification"
文献类型:期刊论文
作者 | Weng, Yuxiang1,2; Han, Xiaofeng1,2; Zhang, Lingyuan3 |
刊名 | Journal of the optical society of america b-optical physics
![]() |
出版日期 | 2008-10-01 |
卷号 | 25期号:10页码:1627-1631 |
ISSN号 | 0740-3224 |
通讯作者 | Weng, yuxiang(yxweng@aphy.iphy.ac.cn) |
英文摘要 | A backward fluorescence collection method is employed in a noncollinear optical parametric amplification-gated femtosecond time-resolved fluorescence spectrometer to determine the detection limit of this recently developed technique. in this way the supercontinuum generation that interferes with the determination of the detection limit is completely excluded, and the achieved upper limit of the detectable photon number with the 150 fs gating pulse is approximately 19. (c) 2008 optical society of america |
WOS研究方向 | Optics |
WOS类目 | Optics |
语种 | 英语 |
WOS记录号 | WOS:000260506400010 |
出版者 | OPTICAL SOC AMER |
URI标识 | http://www.irgrid.ac.cn/handle/1471x/2373660 |
专题 | 物理研究所 |
通讯作者 | Weng, Yuxiang |
作者单位 | 1.Chinese Acad Sci, Inst Phys, Lab Soft Matter Phys, Beijing 100080, Peoples R China 2.Beijing Natl Lab Condensed Phys, Beijing 100080, Peoples R China 3.Georgia So Univ, Dept Phys, Statesboro, GA 30460 USA |
推荐引用方式 GB/T 7714 | Weng, Yuxiang,Han, Xiaofeng,Zhang, Lingyuan. Determination of the detection limit for a noncollinear optical parametric amplification-gated femtosecond time-resolved fluorescence spectrometer - reply to the comment on "ultrasensitive femtosecond time-resolved fluorescence spectroscopy for relaxation processes by using parametric amplification"[J]. Journal of the optical society of america b-optical physics,2008,25(10):1627-1631. |
APA | Weng, Yuxiang,Han, Xiaofeng,&Zhang, Lingyuan.(2008).Determination of the detection limit for a noncollinear optical parametric amplification-gated femtosecond time-resolved fluorescence spectrometer - reply to the comment on "ultrasensitive femtosecond time-resolved fluorescence spectroscopy for relaxation processes by using parametric amplification".Journal of the optical society of america b-optical physics,25(10),1627-1631. |
MLA | Weng, Yuxiang,et al."Determination of the detection limit for a noncollinear optical parametric amplification-gated femtosecond time-resolved fluorescence spectrometer - reply to the comment on "ultrasensitive femtosecond time-resolved fluorescence spectroscopy for relaxation processes by using parametric amplification"".Journal of the optical society of america b-optical physics 25.10(2008):1627-1631. |
入库方式: iSwitch采集
来源:物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。