Dynamic and thermodynamic characteristics of the moving-coil linear compressor for the pulse tube cryocooler: part b - experimental verifications

文献类型:期刊论文

作者Dang, Haizheng1; Zhang, Lei1,2; Tan, Jun1,2
刊名International journal of refrigeration-revue internationale du froid
出版日期2016-09-01
卷号69页码:497-504
ISSN号0140-7007
关键词Dynamic and thermodynamic characteristics Moving-coil linear compressor Stirling-type pulse tube cryocooler Experimental verification
DOI10.1016/j.ijrefrig.2015.12.020
通讯作者Dang, haizheng(haizheng.dang@mail.sitp.ac.cn)
英文摘要Experimental investigations are carried out to verify the theoretical analyses and modeling conducted in part a. some empirical corrections are made and two sets of experiments are arranged based on the same compressor coupled with two different coaxial cold fingers typically operating at 80 k and 60 k, respectively. the variations of phi, delta p, i, theta; the input electric power, eta(motor); the cooling capacity and eta(carnot) with the operating frequency at the given cooling temperatures are tested and compared with the simulation results, and fairly good agreements are found in both cases. the effects of the cooling temperature on these characteristics are also tested and discussed. experimental results verify the validity of the theoretical investigations in part a. the results also indicate that the theoretical studies can apply to wide ranges of both the operating frequency and the cooling temperature. (c) 2016 elsevier ltd and iir. all rights reserved.
WOS研究方向Thermodynamics ; Engineering
WOS类目Thermodynamics ; Engineering, Mechanical
语种英语
出版者ELSEVIER SCI LTD
WOS记录号WOS:000381838200039
URI标识http://www.irgrid.ac.cn/handle/1471x/2374383
专题中国科学院大学
通讯作者Dang, Haizheng
作者单位1.Chinese Acad Sci, Shanghai Inst Tech Phys, Natl Lab Infrared Phys, 500 Yutian Rd, Shanghai 200083, Peoples R China
2.Univ Chinese Acad Sci, 19A Yuquan Rd, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Dang, Haizheng,Zhang, Lei,Tan, Jun. Dynamic and thermodynamic characteristics of the moving-coil linear compressor for the pulse tube cryocooler: part b - experimental verifications[J]. International journal of refrigeration-revue internationale du froid,2016,69:497-504.
APA Dang, Haizheng,Zhang, Lei,&Tan, Jun.(2016).Dynamic and thermodynamic characteristics of the moving-coil linear compressor for the pulse tube cryocooler: part b - experimental verifications.International journal of refrigeration-revue internationale du froid,69,497-504.
MLA Dang, Haizheng,et al."Dynamic and thermodynamic characteristics of the moving-coil linear compressor for the pulse tube cryocooler: part b - experimental verifications".International journal of refrigeration-revue internationale du froid 69(2016):497-504.

入库方式: iSwitch采集

来源:中国科学院大学

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。