Experimental study of the influence of cold heat exchanger geometry on the performance of a co-axial pulse tube cooler
文献类型:期刊论文
作者 | Pang, Xiaomin1,2; Dai, Wei1; Wang, Xiaotao1; Vanapalli, S.3; Luo, Ercang1 |
刊名 | Cryogenics
![]() |
出版日期 | 2016-09-01 |
卷号 | 78页码:78-82 |
关键词 | Cold heat exchanger Co-axial Pulse tube cooler Slot number Slot width |
ISSN号 | 0011-2275 |
DOI | 10.1016/j.cryogenics.2016.07.008 |
通讯作者 | Dai, wei(cryodw@mail.ipc.ac.cn) |
英文摘要 | Improving the performance of the pulse tube cooler is one of the important objectives of the current studies. besides the phase shifters and regenerators, heat exchangers also play an important role in determining the system efficiency and cooling capacity. a series of experiments on a 10 w @ 77 k class co-axial type pulse tube cooler with different cold heat exchanger geometries are presented in this paper. the cold heat exchangers are made from a copper block with radial slots, cut through using electrical discharge machining. different slot widths varying from 0.12 mm to 0.4 mm and different slot numbers varying from around 20-60 are investigated, while the length of cold heat exchangers are kept the same. the cold heat exchanger geometry is classified into three groups, namely, constant heat transfer area, constant porosity and constant slot width. the study reveals that a large channel width of 0.4 mm (about ten times the thermal penetration depth of helium gas at 77 k, 100 hz and 3.5 mpa) shows poor performance, the other results show complicated interaction effects between slot width and slot number. these systematic comparison experiments provide a useful reference for selecting a cold heat exchanger geometry in a practical cooler. (c) 2016 elsevier ltd. all rights reserved. |
WOS关键词 | REFRIGERATOR ; FLOW |
WOS研究方向 | Thermodynamics ; Physics |
WOS类目 | Thermodynamics ; Physics, Applied |
语种 | 英语 |
WOS记录号 | WOS:000383297800009 |
出版者 | ELSEVIER SCI LTD |
URI标识 | http://www.irgrid.ac.cn/handle/1471x/2376256 |
专题 | 中国科学院大学 |
通讯作者 | Dai, Wei |
作者单位 | 1.Chinese Acad Sci, Tech Inst Phys & Chem, Key Lab Cryogen, Zhong Guan Cun Dong Rd 29, Beijing 100190, Peoples R China 2.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China 3.Univ Twente, Fac Sci & Technol, Energy Mat & Syst, NL-7500 AE Enschede, Netherlands |
推荐引用方式 GB/T 7714 | Pang, Xiaomin,Dai, Wei,Wang, Xiaotao,et al. Experimental study of the influence of cold heat exchanger geometry on the performance of a co-axial pulse tube cooler[J]. Cryogenics,2016,78:78-82. |
APA | Pang, Xiaomin,Dai, Wei,Wang, Xiaotao,Vanapalli, S.,&Luo, Ercang.(2016).Experimental study of the influence of cold heat exchanger geometry on the performance of a co-axial pulse tube cooler.Cryogenics,78,78-82. |
MLA | Pang, Xiaomin,et al."Experimental study of the influence of cold heat exchanger geometry on the performance of a co-axial pulse tube cooler".Cryogenics 78(2016):78-82. |
入库方式: iSwitch采集
来源:中国科学院大学
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。