Theoretical and experimental investigations on the partial scaling method for the oxford-type moving-coil linear compressor
文献类型:期刊论文
作者 | Zhang, Lei1,2; Dang, Haizheng1; Tan, Jun1,2; Song, Yuyao1; Zhou, Binglu1; Zou, Ruiqi1; Zhao, Yibo1,2; Gao, Zhiqian1,2; Bao, Dingli1,2; Li, Ning1 |
刊名 | Cryogenics
![]() |
出版日期 | 2015-07-01 |
卷号 | 69页码:26-35 |
关键词 | Partial scaling method Oxford-type moving-coil linear compressor Pulse tube cryocooler |
ISSN号 | 0011-2275 |
DOI | 10.1016/j.cryogenics.2015.03.004 |
通讯作者 | Dang, haizheng(haizheng.dang@mail.sitp.ac.cn) |
英文摘要 | This paper puts forward the partial scaling method of the oxford-type moving-coil linear compressor for pulse tube cryocoolers and analyzes the related principles. the systematic experimental investigations are further made to verify the analyses. one of the typical compressors developed in the authors' laboratory is chosen to be scaled, and then coupled with the original pulse tube cold finger. at the typical operating temperature of 80 k for the pulse tube cold finger, the scaled compressor's maximum input electric power increases from 236.7 w to 370.0 w, and the cooling power is enhanced from 10.0 w to 15.0 w. the motor efficiency decreases from 78% to 73%, but the average cooling efficiency slightly increases from 11% to 12% of carnot efficiency due to a better match between scaled compressor and original cold finger. the rationality and feasibility of the partial scaling method have been verified by the theoretical analyses and experimental investigations. (c) 2015 elsevier ltd. all rights reserved. |
WOS研究方向 | Thermodynamics ; Physics |
WOS类目 | Thermodynamics ; Physics, Applied |
语种 | 英语 |
WOS记录号 | WOS:000356986400004 |
出版者 | ELSEVIER SCI LTD |
URI标识 | http://www.irgrid.ac.cn/handle/1471x/2376419 |
专题 | 中国科学院大学 |
通讯作者 | Dang, Haizheng |
作者单位 | 1.Chinese Acad Sci, Shanghai Inst Tech Phys, Natl Lab Infrared Phys, Shanghai 200083, Peoples R China 2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China |
推荐引用方式 GB/T 7714 | Zhang, Lei,Dang, Haizheng,Tan, Jun,et al. Theoretical and experimental investigations on the partial scaling method for the oxford-type moving-coil linear compressor[J]. Cryogenics,2015,69:26-35. |
APA | Zhang, Lei.,Dang, Haizheng.,Tan, Jun.,Song, Yuyao.,Zhou, Binglu.,...&Li, Ning.(2015).Theoretical and experimental investigations on the partial scaling method for the oxford-type moving-coil linear compressor.Cryogenics,69,26-35. |
MLA | Zhang, Lei,et al."Theoretical and experimental investigations on the partial scaling method for the oxford-type moving-coil linear compressor".Cryogenics 69(2015):26-35. |
入库方式: iSwitch采集
来源:中国科学院大学
浏览0