Investigation of an innovative method for dc flow suppression of double-inlet pulse tube coolers
文献类型:期刊论文
作者 | Hu, J. Y.; Luo, E. C.; Wu, Z. H.; Dai, W.; Zhu, S. L. |
刊名 | Cryogenics
![]() |
出版日期 | 2007-05-01 |
卷号 | 47期号:5-6页码:287-291 |
关键词 | Pulse tube cooler Double-inlet Dc flow Acoustical transparent membrane |
ISSN号 | 0011-2275 |
DOI | 10.1016/j.cryogenics.2007.03.002 |
通讯作者 | Luo, e. c.(ecluo@cl.cryo.ac.cn) |
英文摘要 | The use of double-inlet mode in the pulse tube cooler opens up a possibility of dc flow circulating around the regenerator and the pulse tube. the dc flow sometimes deteriorates the performance of the cryocooler because such a steady flow adds an unwanted thermal load to the cold heat exchanger. it seems that this problem is still not well solved although a lot of effort has been made. here we introduce a membrane-barrier method for dc flow suppression in double-inlet pulse tube coolers. an elastic membrane is installed between the pulse tube cooler inlet and the double-inlet valve to break the closed-loop flow path of dc flow. the membrane is acoustically transparent, but would block the dc flow completely. thus the dc flow is thoroughly suppressed and the merit of double-inlet mode is remained. with this method, a temperature reduction of tens of kelvin was obtained in our single-stage pulse tube cooler and the lowest temperature reached 29.8 k. (c) 2007 elsevier ltd. all rights reserved. |
WOS关键词 | REFRIGERATOR |
WOS研究方向 | Thermodynamics ; Physics |
WOS类目 | Thermodynamics ; Physics, Applied |
语种 | 英语 |
WOS记录号 | WOS:000248881400003 |
出版者 | ELSEVIER SCI LTD |
URI标识 | http://www.irgrid.ac.cn/handle/1471x/2380242 |
专题 | 中国科学院大学 |
通讯作者 | Luo, E. C. |
作者单位 | 1.Chinese Acad Sci, Tech Inst Phys & Chem, Beijing 100080, Peoples R China 2.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China |
推荐引用方式 GB/T 7714 | Hu, J. Y.,Luo, E. C.,Wu, Z. H.,et al. Investigation of an innovative method for dc flow suppression of double-inlet pulse tube coolers[J]. Cryogenics,2007,47(5-6):287-291. |
APA | Hu, J. Y.,Luo, E. C.,Wu, Z. H.,Dai, W.,&Zhu, S. L..(2007).Investigation of an innovative method for dc flow suppression of double-inlet pulse tube coolers.Cryogenics,47(5-6),287-291. |
MLA | Hu, J. Y.,et al."Investigation of an innovative method for dc flow suppression of double-inlet pulse tube coolers".Cryogenics 47.5-6(2007):287-291. |
入库方式: iSwitch采集
来源:中国科学院大学
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。