Improvement of proteome coverage using hydrophobic monolithic columns in shotgun proteome analysis
文献类型:期刊论文
作者 | Wang, Fangjun; Dong, Jing; Ye, Mingliang; Wu, Ren'an; Zou, Hanfa |
刊名 | journal of chromatography a
![]() |
出版日期 | 2009-05-01 |
卷号 | 1216期号:18页码:3887-3894 |
关键词 | Methacrylate Porogenic solvent Monolithic column Shotgun proteome analysis Proteome coverage Online multidimensional separation |
ISSN号 | 0021-9673 |
产权排序 | 1;1 |
通讯作者 | 邹汉法 |
英文摘要 | monolithic columns are widely used in shotgun proteome analysis. however, it is difficult to increase the separation capability and proteome coverage by using conventionally organic polymer-based monolithic column due to the difficulty of controlling homogeneity of the overall pore structure (both pores and microglobules), which leads to relatively low column efficiency. therefore, we studied the effect of constitute and percentage of porogenic solvent, functional monomer, column length, and separation gradient on the peak capacity and proteome coverage by methacrylate-based reversed phase monolithic columns. it was demonstrated that the porous property of the hydrophobic monolith, which was mainly determined by the porogenic solvent, was crucial to the proteome coverage when similar methacrylate monomer was utilized and a ternary porogenic solvent was adopted to prepare c12 monolithic column with relatively homogeneous overall pore structure. it was also shown that high proteome coverage could be reliably obtained with online multidimensional separation using totally monolithic columns system with the length of analytical column at 85 cm and reversed phase separation gradient at 210 min. (c) 2009 elsevier b.v. all rights reserved. |
WOS标题词 | science & technology ; life sciences & biomedicine ; physical sciences |
类目[WOS] | biochemical research methods ; chemistry, analytical |
研究领域[WOS] | biochemistry & molecular biology ; chemistry |
关键词[WOS] | electron-capture dissociation ; rigid polymer monoliths ; chromatography-mass spectrometry ; capillary liquid-chromatography ; stationary phases ; nanoelectrospray ionization ; identification technology ; separation media ; peak-capacity ; trap column |
收录类别 | SCI |
原文出处 | true |
语种 | 英语 |
WOS记录号 | WOS:000265699900028 |
公开日期 | 2010-11-30 |
源URL | [http://159.226.238.44/handle/321008/101615] ![]() |
专题 | 大连化学物理研究所_中国科学院大连化学物理研究所 |
作者单位 | Chinese Acad Sci, Dalian Inst Chem Phys, Natl Chromatog Res & Anal Ctr, Key Lab Separat Sci Analyt Chem, Dalian 116023, Peoples R China |
推荐引用方式 GB/T 7714 | Wang, Fangjun,Dong, Jing,Ye, Mingliang,et al. Improvement of proteome coverage using hydrophobic monolithic columns in shotgun proteome analysis[J]. journal of chromatography a,2009,1216(18):3887-3894. |
APA | Wang, Fangjun,Dong, Jing,Ye, Mingliang,Wu, Ren'an,&Zou, Hanfa.(2009).Improvement of proteome coverage using hydrophobic monolithic columns in shotgun proteome analysis.journal of chromatography a,1216(18),3887-3894. |
MLA | Wang, Fangjun,et al."Improvement of proteome coverage using hydrophobic monolithic columns in shotgun proteome analysis".journal of chromatography a 1216.18(2009):3887-3894. |
入库方式: OAI收割
来源:大连化学物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。