Fiber-optic fluorescence sensor for dissolved oxygen detection based on fluorinated xerogel immobilized with ruthenium (II) complex
文献类型:期刊论文
作者 | Xiong, Yan; Xu, Jing; Zhu, Dao-qian; Duan, Chun-feng; Guan, Ya-feng |
刊名 | journal of sol-gel science and technology
![]() |
出版日期 | 2010-02-01 |
卷号 | 53期号:2页码:441-447 |
关键词 | Fiber-optic sensor Dissolved oxygen detection Two-fiber probe Fluorinated xerogel Ruthenium (II) complex |
产权排序 | 1;1 |
通讯作者 | 关亚风 |
英文摘要 | a fiber-optic sensor based on fluorescence quenching was designed for dissolved oxygen (do) detection. the fluorinated xerogel-based sensing film of the present sensor was prepared from 3, 3, 3-trifluoropropyltrimethoxysilane (tfp-trimos). oxygen-sensitive fluorophores of tris (2, 2'- bipyridine) ruthenium (ii) (ru(bpy) (3) (2+) ) were immobilized in the sensing film and the emission fluorescence was quenched by dissolved oxygen. in the sensor fabrication, a two-fiber probe was employed to obtain the best fluorescence collection efficiency and the sensing film was attached to the probe end. scanning electron microscope (sem), uv-vis absorption spectroscopy (uv-vis) and fourier transform infrared spectroscopy (ftir) measurements have been used to characterize the sensing film. the sensor sensitivity is quantified by i (deoxy)/i (oxy), where i (deoxy) and i (oxy) represented the detected fluorescence intensities in fully deoxygenated and fully oxygenated environments, respectively. compared with tetramethoxysilane (tmos) and methyltriethoxysilane (mtms)-derived sensing films, tfp-trimos-based sensor exhibited excellent performances in dissolved oxygen detection with short response time of 4 s, low limit of detection (lod) of 0.04 ppm (r.s.d. = 2.5%), linear stern-volmer calibration plot from 0 to 40 ppm and long-term stability during the past 10 months. the reasons for the preferable performances of tfp-trimos-based sensing film were discussed. |
WOS标题词 | science & technology ; technology |
类目[WOS] | materials science, ceramics |
研究领域[WOS] | materials science |
关键词[WOS] | trifluoroethylmethacrylate copolymer film ; luminescence change ; optical sensor ; thin-films ; matrix |
收录类别 | SCI |
原文出处 | false |
语种 | 英语 |
WOS记录号 | WOS:000274318400043 |
公开日期 | 2010-11-30 |
源URL | [http://159.226.238.44/handle/321008/103419] ![]() |
专题 | 大连化学物理研究所_中国科学院大连化学物理研究所 |
作者单位 | Chinese Acad Sci, Dalian Inst Chem Phys, Dept Instrumentat & Analyt Chem, Key Lab Separat & Anal, Dalian 116023, Peoples R China |
推荐引用方式 GB/T 7714 | Xiong, Yan,Xu, Jing,Zhu, Dao-qian,et al. Fiber-optic fluorescence sensor for dissolved oxygen detection based on fluorinated xerogel immobilized with ruthenium (II) complex[J]. journal of sol-gel science and technology,2010,53(2):441-447. |
APA | Xiong, Yan,Xu, Jing,Zhu, Dao-qian,Duan, Chun-feng,&Guan, Ya-feng.(2010).Fiber-optic fluorescence sensor for dissolved oxygen detection based on fluorinated xerogel immobilized with ruthenium (II) complex.journal of sol-gel science and technology,53(2),441-447. |
MLA | Xiong, Yan,et al."Fiber-optic fluorescence sensor for dissolved oxygen detection based on fluorinated xerogel immobilized with ruthenium (II) complex".journal of sol-gel science and technology 53.2(2010):441-447. |
入库方式: OAI收割
来源:大连化学物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。