Characterization of a 300 hz thermoacoustically-driven pulse tube cooler
文献类型:期刊论文
作者 | Zhu, S. L.1,2; Yu, G. Y.1,2; Dai, W.1; Luo, E. C.1; Wu, Z. H.1; Zhang, X. D.1,2 |
刊名 | Cryogenics
![]() |
出版日期 | 2009 |
卷号 | 49期号:1页码:51-54 |
关键词 | Thermoacoustics Pulse tube cooler High frequency |
ISSN号 | 0011-2275 |
DOI | 10.1016/j.cryogenics.2008.10.001 |
通讯作者 | Luo, e. c.(ecluo@cl.cryo.ac.cn) |
英文摘要 | This article introduces our recent experimental advances on a 300 hz pulse tube cooler driven by a thermoacoustic standing-wave engine. after some modifications on the engine, the integral system performance is improved, which leads to a better cooling performance of the high frequency pulse tube cooler compared with that in former reports. cooling powers of the pulse tube cooler with different operating conditions have been measured in detail for the first time. so far, a lowest no-load temperature of 68 k and a maximum cooling power of 1.16 w at 80 k have been obtained with the mean pressure and the heating power being 4.1 wa and 1 kw, respectively. (c) 2008 elsevier ltd. all rights reserved. |
WOS研究方向 | Thermodynamics ; Physics |
WOS类目 | Thermodynamics ; Physics, Applied |
语种 | 英语 |
WOS记录号 | WOS:000262884800009 |
出版者 | ELSEVIER SCI LTD |
URI标识 | http://www.irgrid.ac.cn/handle/1471x/2398833 |
专题 | 中国科学院大学 |
通讯作者 | Luo, E. C. |
作者单位 | 1.Tech Inst Phys & Chem CAS, Beijing 100190, Peoples R China 2.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China |
推荐引用方式 GB/T 7714 | Zhu, S. L.,Yu, G. Y.,Dai, W.,et al. Characterization of a 300 hz thermoacoustically-driven pulse tube cooler[J]. Cryogenics,2009,49(1):51-54. |
APA | Zhu, S. L.,Yu, G. Y.,Dai, W.,Luo, E. C.,Wu, Z. H.,&Zhang, X. D..(2009).Characterization of a 300 hz thermoacoustically-driven pulse tube cooler.Cryogenics,49(1),51-54. |
MLA | Zhu, S. L.,et al."Characterization of a 300 hz thermoacoustically-driven pulse tube cooler".Cryogenics 49.1(2009):51-54. |
入库方式: iSwitch采集
来源:中国科学院大学
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。