中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Determination of trace amino acids in human serum by a selective and sensitive pre-column derivatization method using HPLC-FLD-MS/MS and derivatization optimization by response surface methodology

文献类型:期刊论文

作者Li, Guoliang ; Cui, Yanyan ; You, Jinmao ; Zhao, Xianen ; Sun, Zhiwei ; Xia, Lian ; Suo, Yourui ; Wang, Xiao
刊名AMINO ACIDS ; Li, GL; Cui, YY; You, JM; Zhao, XN; Sun, ZW; Xia, LA; Suo, YR; Wang, X.Determination of trace amino acids in human serum by a selective and sensitive pre-column derivatization method using HPLC-FLD-MS/MS and derivatization optimization by response surface methodology,AMINO ACIDS,2011,40(4):1185-1193
出版日期2011-04-01
英文摘要Analysis of trace amino acids (AA) in physiological fluids has received more attention, because the analysis of these compounds could provide fundamental and important information for medical, biological, and clinical researches. More accurate method for the determination of those compounds is highly desirable and valuable. In the present study, we developed a selective and sensitive method for trace AA determination in biological samples using 2-[2-(7H-dibenzo [a,g]carbazol-7-yl)-ethoxy] ethyl chloroformate (DBCEC) as labeling reagent by HPLC-FLD-MS/MS. Response surface methodology (RSM) was first employed to optimize the derivatization reaction between DBCEC and AA. Compared with traditional single-factor design, RSM was capable of lessening laborious, time and reagents consumption. The complete derivatization can be achieved within 6.3 min at room temperature. In conjunction with a gradient elution, a baseline resolution of 20 AA containing acidic, neutral, and basic AA was achieved on a reversed-phase Hypersil BDS C(18) column. This method showed excellent reproducibility and correlation coefficient, and offered the exciting detection limits of 0.19-1.17 fmol/mu L. The developed method was successfully applied to determinate AA in human serum. The sensitive and prognostic index of serum AA for liver diseases has also been discussed.; Analysis of trace amino acids (AA) in physiological fluids has received more attention, because the analysis of these compounds could provide fundamental and important information for medical, biological, and clinical researches. More accurate method for the determination of those compounds is highly desirable and valuable. In the present study, we developed a selective and sensitive method for trace AA determination in biological samples using 2-[2-(7H-dibenzo [a,g]carbazol-7-yl)-ethoxy] ethyl chloroformate (DBCEC) as labeling reagent by HPLC-FLD-MS/MS. Response surface methodology (RSM) was first employed to optimize the derivatization reaction between DBCEC and AA. Compared with traditional single-factor design, RSM was capable of lessening laborious, time and reagents consumption. The complete derivatization can be achieved within 6.3 min at room temperature. In conjunction with a gradient elution, a baseline resolution of 20 AA containing acidic, neutral, and basic AA was achieved on a reversed-phase Hypersil BDS C(18) column. This method showed excellent reproducibility and correlation coefficient, and offered the exciting detection limits of 0.19-1.17 fmol/mu L. The developed method was successfully applied to determinate AA in human serum. The sensitive and prognostic index of serum AA for liver diseases has also been discussed.
源URL[http://ir.nwipb.ac.cn//handle/363003/1564]  
专题西北高原生物研究所_中国科学院西北高原生物研究所
推荐引用方式
GB/T 7714
Li, Guoliang,Cui, Yanyan,You, Jinmao,et al. Determination of trace amino acids in human serum by a selective and sensitive pre-column derivatization method using HPLC-FLD-MS/MS and derivatization optimization by response surface methodology[J]. AMINO ACIDS, Li, GL; Cui, YY; You, JM; Zhao, XN; Sun, ZW; Xia, LA; Suo, YR; Wang, X.Determination of trace amino acids in human serum by a selective and sensitive pre-column derivatization method using HPLC-FLD-MS/MS and derivatization optimization by response surface methodology,AMINO ACIDS,2011,40(4):1185-1193,2011.
APA Li, Guoliang.,Cui, Yanyan.,You, Jinmao.,Zhao, Xianen.,Sun, Zhiwei.,...&Wang, Xiao.(2011).Determination of trace amino acids in human serum by a selective and sensitive pre-column derivatization method using HPLC-FLD-MS/MS and derivatization optimization by response surface methodology.AMINO ACIDS.
MLA Li, Guoliang,et al."Determination of trace amino acids in human serum by a selective and sensitive pre-column derivatization method using HPLC-FLD-MS/MS and derivatization optimization by response surface methodology".AMINO ACIDS (2011).

入库方式: OAI收割

来源:西北高原生物研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。