中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Sensitive determination of melamine leached from tableware by reversed phase high-performance liquid chromatography using 10-methyl-acridone-2-sulfonyl chloride as a pre-column fluorescent labeling reagent

文献类型:期刊论文

作者Zhang, Shijuan ; Yu, Zhaoqiang ; Hu, Na ; Sun, Yuanpeng ; Suo, Yourui ; You, Jinmao
刊名FOOD CONTROL ; Zhang, SJ; Yu, ZQ; Hu, N; Sun, YP; Suo, YR; You, JM.Sensitive determination of melamine leached from tableware by reversed phase high-performance liquid chromatography using 10-methyl-acridone-2-sulfonyl chloride as a pre-column fluorescent labeling reagent,FOOD CONTROL,2014,39():25
出版日期2014-05-01
英文摘要A new and sensitive pre-column derivatization method was developed for the analysis of melamine leached from tableware by high performance liquid chromatography (HPLC) with fluorescence detection. The HPLC sensitivity was greatly enhanced by introducing 10-methyl-acridone-2-sulfonyl chloride (MASC) with excellent fluorescence property into the melamine molecule. Meanwhile, derivatization also greatly increased the hydrophobicity of melamine. Therefore, the common reversed phase column can be used for the HPLC analysis of highly hydrophilic melamine. The detection limit obtained by the proposed method was lower than 0.40 mu g/L. This is the first time that HPLC with fluorescence detection was applied to the analysis of melamine. The proposed method was successfully applied to the analysis of melamine leached from tableware. The results indicated that the leaching of melamine from tableware was obvious when hot water or milk was added. (C) 2013 Elsevier Ltd. All rights reserved.; A new and sensitive pre-column derivatization method was developed for the analysis of melamine leached from tableware by high performance liquid chromatography (HPLC) with fluorescence detection. The HPLC sensitivity was greatly enhanced by introducing 10-methyl-acridone-2-sulfonyl chloride (MASC) with excellent fluorescence property into the melamine molecule. Meanwhile, derivatization also greatly increased the hydrophobicity of melamine. Therefore, the common reversed phase column can be used for the HPLC analysis of highly hydrophilic melamine. The detection limit obtained by the proposed method was lower than 0.40 mu g/L. This is the first time that HPLC with fluorescence detection was applied to the analysis of melamine. The proposed method was successfully applied to the analysis of melamine leached from tableware. The results indicated that the leaching of melamine from tableware was obvious when hot water or milk was added. (C) 2013 Elsevier Ltd. All rights reserved.
源URL[http://ir.nwipb.ac.cn/handle/363003/4238]  
专题西北高原生物研究所_中国科学院西北高原生物研究所
推荐引用方式
GB/T 7714
Zhang, Shijuan,Yu, Zhaoqiang,Hu, Na,et al. Sensitive determination of melamine leached from tableware by reversed phase high-performance liquid chromatography using 10-methyl-acridone-2-sulfonyl chloride as a pre-column fluorescent labeling reagent[J]. FOOD CONTROL, Zhang, SJ; Yu, ZQ; Hu, N; Sun, YP; Suo, YR; You, JM.Sensitive determination of melamine leached from tableware by reversed phase high-performance liquid chromatography using 10-methyl-acridone-2-sulfonyl chloride as a pre-column fluorescent labeling reagent,FOOD CONTROL,2014,39():25,2014.
APA Zhang, Shijuan,Yu, Zhaoqiang,Hu, Na,Sun, Yuanpeng,Suo, Yourui,&You, Jinmao.(2014).Sensitive determination of melamine leached from tableware by reversed phase high-performance liquid chromatography using 10-methyl-acridone-2-sulfonyl chloride as a pre-column fluorescent labeling reagent.FOOD CONTROL.
MLA Zhang, Shijuan,et al."Sensitive determination of melamine leached from tableware by reversed phase high-performance liquid chromatography using 10-methyl-acridone-2-sulfonyl chloride as a pre-column fluorescent labeling reagent".FOOD CONTROL (2014).

入库方式: OAI收割

来源:西北高原生物研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。