Determination of Free Aliphatic Amines in Environmental Water by EASC Derivatization and Identification with LC-APCI-MS

文献类型:期刊论文

作者Zhao Huai-Xin1; Sun Xue-Jun1; Sun Zhi-Wei2,3; Yan Tao1; Zhang Zai-Qing1; Liu Qin-Ze1; Suo You-Rui2; Li Yu-Lin2; You Jin-Mao1,2
刊名chemical journal of chinese universities-chinese
出版日期2009-04-10
卷号30期号:4页码:675-681
关键词High performance liquid chromatography/ion-trap mass spectrometry Fluorescence detection Pre-column derivatization 10-ethyl-9-oxo-9, 10-dihydroacridine-2-sulfonyl chloride Aliphatic amine
ISSN号0251-0790
中文摘要on a reversed-phase hypersil bds c(18) (4.6 mm x 200 mm, 10 mu m i.d.) column, 12 aliphatic amines were derivatized using 10-ethyl-9-oxo-9,10-dihydroacriditie-2-sulfonyl chloride(easc) as a new pre-column derivatization reagent. the complete baseline resolution was obtained in conjunction with a gradient elution with acetonitrile/h(2)o as mobile phase within 20 min. the optimum excitation and emission wavelengths were at lambda(ex)/lambda(em) = 270 nm/430 nm. comparing with the widely used dansyl-cl, easc has stronger photoluminescence characteristics(ultraviolet and fluorescence) : uv(easc)/uv(dansyl-cl) = 3.2 (uv: ultraviolet absorption intensity); i(easc/i(dansyl-cl) = 30.0: 1-105. 4:1 (i: relative fluorescence intensity); fluorescence quantum yield: phi(f)(easc)/phi(f)(dansyl-cl) = 43.0:1. fast and accurate quantitative analysis of aliphatic amines with fluorescence and corresponding post-column ion trap mass spectrometry(lc-apci-ms) were obtained. easc-amines exhibited stronger mass spectrometric sensitivity relative to that of dansyl-amine derivatives: ms(easc)/ms(dansyl-cl) = 1. 6: 1-6. 2: 1 times(ms: relative intensity of ion current). the established method for the determination of aliphatic amines in environmental water samples exhibited good reproducibility and recovery. excellent linear responses were observed with the correlation coefficients >0.9995. the detection limits(at signal-to-noise of 3: 1) were at levels of 4.0-12.7 fmol.
英文摘要on a reversed-phase hypersil bds c(18) (4.6 mm x 200 mm, 10 mu m i.d.) column, 12 aliphatic amines were derivatized using 10-ethyl-9-oxo-9,10-dihydroacriditie-2-sulfonyl chloride(easc) as a new pre-column derivatization reagent. the complete baseline resolution was obtained in conjunction with a gradient elution with acetonitrile/h(2)o as mobile phase within 20 min. the optimum excitation and emission wavelengths were at lambda(ex)/lambda(em) = 270 nm/430 nm. comparing with the widely used dansyl-cl, easc has stronger photoluminescence characteristics(ultraviolet and fluorescence) : uv(easc)/uv(dansyl-cl) = 3.2 (uv: ultraviolet absorption intensity); i(easc/i(dansyl-cl) = 30.0: 1-105. 4:1 (i: relative fluorescence intensity); fluorescence quantum yield: phi(f)(easc)/phi(f)(dansyl-cl) = 43.0:1. fast and accurate quantitative analysis of aliphatic amines with fluorescence and corresponding post-column ion trap mass spectrometry(lc-apci-ms) were obtained. easc-amines exhibited stronger mass spectrometric sensitivity relative to that of dansyl-amine derivatives: ms(easc)/ms(dansyl-cl) = 1. 6: 1-6. 2: 1 times(ms: relative intensity of ion current). the established method for the determination of aliphatic amines in environmental water samples exhibited good reproducibility and recovery. excellent linear responses were observed with the correlation coefficients >0.9995. the detection limits(at signal-to-noise of 3: 1) were at levels of 4.0-12.7 fmol.
WOS标题词science & technology ; physical sciences
类目[WOS]chemistry, multidisciplinary
研究领域[WOS]chemistry
关键词[WOS]performance liquid-chromatography ; dansyl chloride ; precolumn derivatization ; fluorescence detection ; derivatives ; ionization
收录类别SCI
语种英语
WOS记录号WOS:000265665700007
公开日期2011-12-13
源URL[http://ir.nwipb.ac.cn//handle/363003/1886]  
专题西北高原生物研究所_中国科学院西北高原生物研究所
作者单位1.Qufu Normal Univ, Coll Chem Sci, Key Lab Life Organ Anal Shandony, Qufu 273165, Peoples R China
2.Chinese Acad Sci, NW Plateau Inst Biol, Xining 810001, Peoples R China
3.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Zhao Huai-Xin,Sun Xue-Jun,Sun Zhi-Wei,et al. Determination of Free Aliphatic Amines in Environmental Water by EASC Derivatization and Identification with LC-APCI-MS[J]. chemical journal of chinese universities-chinese,2009,30(4):675-681.
APA Zhao Huai-Xin.,Sun Xue-Jun.,Sun Zhi-Wei.,Yan Tao.,Zhang Zai-Qing.,...&You Jin-Mao.(2009).Determination of Free Aliphatic Amines in Environmental Water by EASC Derivatization and Identification with LC-APCI-MS.chemical journal of chinese universities-chinese,30(4),675-681.