Serum or plasma, what is the difference? Investigations to facilitate the sample material selection decision making process for metabolomics studies and beyond
文献类型:期刊论文
作者 | Liu, Xinyu1; Hoene, Miriam2; Wang, Xiaolin1; Yin, Peiyuan1; Xu, Guowang1; Haering, Hans-Ulrich2,3,4; Lehmann, Rainer2,3,4 |
刊名 | ANALYTICA CHIMICA ACTA
![]() |
出版日期 | 2018-12-11 |
卷号 | 1037页码:293-300 |
关键词 | Plasma Serum Metabolic profiling Sample material selection Metabolomics |
ISSN号 | 0003-2670 |
DOI | 10.1016/j.aca.2018.03.009 |
通讯作者 | Xu, Guowang(xugw@dicp.ac.cn) ; Lehmann, Rainer(rainer.lehmann@med.uni-tuebingen.de) |
英文摘要 | In analytical chemistry serum as well as plasma are recommended as sample material of choice. However, blood processing for the generation of serum or plasma is rather different. Whether plasma or serum is the preferable sample material is still controversial discussed. We performed in paired samples three UHPLC-mass spectrometry-driven metabolomics studies. In study 1 metabolite profiles of serum vs plasma were compared. 46% out of 216 identified metabolites showed significant different levels (paired Wilcoxon signed-rank test, p < 0.05, FDR <0.01) with only three metabolites (methionine, C2:0- and C3:0-carnitine) showing lower levels in serum. In study 2 comparison of three different serum blood collection tubes revealed that coagulation and associated processes distinctly alter metabolite levels depending on the tube-specific clotting process. Most pronounced differences were found for the dipeptide phenylalanine-phenylalanine (highest levels in silicate containing serum blood collection tubes). In study 3 possible adverse effects of platelets, which still remain in standard plasma even after correct processing, were investigated. No differences in a pattern of 216 metabolites were detected in the comparison of standard and platelet-free plasma (PFP). Our results give novel insights in fundamental differences between serum and plasma, thereby providing valuable information for analytical chemists for decision making to either use serum or plasma before starting complex and time-consuming analytical investigations. (C) 2018 Elsevier B.V. All rights reserved. |
WOS关键词 | MASS-SPECTROMETRY ; HUMAN BLOOD ; GAS-CHROMATOGRAPHY ; COLLECTION |
资助项目 | National Key Research and Development Program of China[2017YFC0906900] ; Sino-German Center for Research Promotion (DFG)[GZ 753] ; Sino-German Center for Research Promotion (NSFC)[LE 1391/1-1] ; German Federal Ministry of Education and Research (BMBF)[01GI0925] ; key foundation and creative research group project (NSFC)[21435006] ; key foundation and creative research group project (NSFC)[21321064] |
WOS研究方向 | Chemistry |
语种 | 英语 |
WOS记录号 | WOS:000446225000030 |
出版者 | ELSEVIER SCIENCE BV |
资助机构 | National Key Research and Development Program of China ; National Key Research and Development Program of China ; Sino-German Center for Research Promotion (DFG) ; Sino-German Center for Research Promotion (DFG) ; Sino-German Center for Research Promotion (NSFC) ; Sino-German Center for Research Promotion (NSFC) ; German Federal Ministry of Education and Research (BMBF) ; German Federal Ministry of Education and Research (BMBF) ; key foundation and creative research group project (NSFC) ; key foundation and creative research group project (NSFC) ; National Key Research and Development Program of China ; National Key Research and Development Program of China ; Sino-German Center for Research Promotion (DFG) ; Sino-German Center for Research Promotion (DFG) ; Sino-German Center for Research Promotion (NSFC) ; Sino-German Center for Research Promotion (NSFC) ; German Federal Ministry of Education and Research (BMBF) ; German Federal Ministry of Education and Research (BMBF) ; key foundation and creative research group project (NSFC) ; key foundation and creative research group project (NSFC) ; National Key Research and Development Program of China ; National Key Research and Development Program of China ; Sino-German Center for Research Promotion (DFG) ; Sino-German Center for Research Promotion (DFG) ; Sino-German Center for Research Promotion (NSFC) ; Sino-German Center for Research Promotion (NSFC) ; German Federal Ministry of Education and Research (BMBF) ; German Federal Ministry of Education and Research (BMBF) ; key foundation and creative research group project (NSFC) ; key foundation and creative research group project (NSFC) ; National Key Research and Development Program of China ; National Key Research and Development Program of China ; Sino-German Center for Research Promotion (DFG) ; Sino-German Center for Research Promotion (DFG) ; Sino-German Center for Research Promotion (NSFC) ; Sino-German Center for Research Promotion (NSFC) ; German Federal Ministry of Education and Research (BMBF) ; German Federal Ministry of Education and Research (BMBF) ; key foundation and creative research group project (NSFC) ; key foundation and creative research group project (NSFC) |
源URL | [http://cas-ir.dicp.ac.cn/handle/321008/166914] ![]() |
专题 | 大连化学物理研究所_中国科学院大连化学物理研究所 |
通讯作者 | Xu, Guowang; Lehmann, Rainer |
作者单位 | 1.Chinese Acad Sci, Dalian Inst Chem Phys, CAS Key Lab Separat Sci Analyt Chem, Dalian 116023, Peoples R China 2.Univ Hosp Tubingen, Cent Lab, Div Clin Chem & Pathobiochem, Hoppe Seyler Str 3, D-72076 Tubingen, Germany 3.German Ctr Diabet Res DZD, Neuherberg, Germany 4.Univ Tubingen, Helmholtz Ctr Munich, Inst Diabet Res & Metab Dis, Core Facil DZD Clin Chem Lab, Tubingen, Germany |
推荐引用方式 GB/T 7714 | Liu, Xinyu,Hoene, Miriam,Wang, Xiaolin,et al. Serum or plasma, what is the difference? Investigations to facilitate the sample material selection decision making process for metabolomics studies and beyond[J]. ANALYTICA CHIMICA ACTA,2018,1037:293-300. |
APA | Liu, Xinyu.,Hoene, Miriam.,Wang, Xiaolin.,Yin, Peiyuan.,Xu, Guowang.,...&Lehmann, Rainer.(2018).Serum or plasma, what is the difference? Investigations to facilitate the sample material selection decision making process for metabolomics studies and beyond.ANALYTICA CHIMICA ACTA,1037,293-300. |
MLA | Liu, Xinyu,et al."Serum or plasma, what is the difference? Investigations to facilitate the sample material selection decision making process for metabolomics studies and beyond".ANALYTICA CHIMICA ACTA 1037(2018):293-300. |
入库方式: OAI收割
来源:大连化学物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。