中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Discovery and validation of potential urinary biomarkers for bladder cancer diagnosis using a pseudotargeted GC-MS metabolomics method

文献类型:期刊论文

作者Xu, Chuanliang3; Zhou, Yang1,2; Song, Ruixiang3; Ma, Chong3; Sun, Yinghao3; Xu, Guowang1; Yin, Peiyuan1; Zhou, Lina1; Zhang, Zhensheng3; Lu, Xin1
刊名ONCOTARGET
出版日期2017
卷号8期号:13页码:20719-20728
关键词Metabolomics Gas Chromatography-mass Spectrometry Biomarker Urine Bladder Cancer
ISSN号1949-2553
DOI10.18632/oncotarget.14988
文献子类Article
英文摘要Bladder cancer (BC) is the second most prevalent malignancy in the urinary system and is associated with significant mortality; thus, there is an urgent need for novel noninvasive diagnostic biomarkers. A urinary pseudotargeted method based on gas chromatography-mass spectrometry was developed and validated for a BC metabolomics study. The method exhibited good repeatability, intraday and interday precision, linearity and metabolome coverage. A total of 76 differential metabolites were defined in the discovery sample set, 58 of which were verified using an independent validation urine set. The verified differential metabolites revealed that energy metabolism, anabolic metabolism and cell redox states were disordered in BC. Based on a binary logistic regression analysis, a four-biomarker panel was defined for the diagnosis of BC. The area under the receiving operator characteristic curve was 0.885 with 88.0% sensitivity and 85.7% specificity in the discovery set and 0.804 with 78.0% sensitivity and 70.3% specificity in the validation set. The combinatorial biomarker panel was also useful for the early diagnosis of BC. This approach can be used to discriminate non-muscle invasive and low-grade BCs from healthy controls with satisfactory sensitivity and specificity. The results show that the developed urinary metabolomics method can be employed to effectively screen noninvasive biomarkers.
WOS关键词GAS CHROMATOGRAPHY/MASS SPECTROMETRY ; PENTOSE-PHOSPHATE PATHWAY ; MASS-SPECTROMETRY ; DECONVOLUTION ; METABOLISM
WOS研究方向Oncology ; Cell Biology
语种英语
WOS记录号WOS:000397642400020
出版者IMPACT JOURNALS LLC
源URL[http://cas-ir.dicp.ac.cn/handle/321008/169394]  
专题大连化学物理研究所_中国科学院大连化学物理研究所
通讯作者Xu, Chuanliang; Lu, Xin
作者单位1.Chinese Acad Sci, Dalian Inst Chem Phys, Key Lab Separat Sci Analyt Chem, Dalian 116023, Peoples R China
2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
3.Secondary Mil Med Univ, Shanghai Changhai Hosp, Dept Urol, Shanghai 200433, Peoples R China
推荐引用方式
GB/T 7714
Xu, Chuanliang,Zhou, Yang,Song, Ruixiang,et al. Discovery and validation of potential urinary biomarkers for bladder cancer diagnosis using a pseudotargeted GC-MS metabolomics method[J]. ONCOTARGET,2017,8(13):20719-20728.
APA Xu, Chuanliang.,Zhou, Yang.,Song, Ruixiang.,Ma, Chong.,Sun, Yinghao.,...&Liu, Xinyu.(2017).Discovery and validation of potential urinary biomarkers for bladder cancer diagnosis using a pseudotargeted GC-MS metabolomics method.ONCOTARGET,8(13),20719-20728.
MLA Xu, Chuanliang,et al."Discovery and validation of potential urinary biomarkers for bladder cancer diagnosis using a pseudotargeted GC-MS metabolomics method".ONCOTARGET 8.13(2017):20719-20728.

入库方式: OAI收割

来源:大连化学物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。