中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
A dielectric barrier discharge ionization based interface for online coupling surface plasmon resonance with mass spectrometry

文献类型:期刊论文

作者Zhang, Yiding1; Xu, Shuting1; Wen, Luhong2; Bai, Yu1; Niu, Li3; Song, Daqian4; Liu, Huwei1
刊名ANALYST
出版日期2016
卷号141期号:11页码:3343-3348
ISSN号0003-2654
DOI10.1039/c6an00561f
文献子类Article
英文摘要The online combination of surface plasmon resonance (SPR) with mass spectrometry (MS) could be beneficial for accurately acquiring molecular interaction data simultaneously with their structural information at high throughputs. In this work, a novel SPR-MS interface was developed using a dielectric barrier discharge ionization (DBDI) source. The DBDI source was placed in front of the MS inlet, generating an ionization plasma jet. A spray tip was set between the DBDI source outlet and the MS inlet, nebulizing the SPR sample solution. Using this interface, samples could first be studied by SPR, then sprayed and ionized, finally analyzed by MS. By analyzing model samples containing small-molecule drugs dissolved in salt containing solutions, the practicability of this SPR-DBDI-MS interface was proved, observing the consistent change of SPR and MS signals. Compared with our previously developed direct analysis in real time (DART) based SPR-MS interface, this new interface exhibited a higher and better tolerance to non-volatile salts, and different ionization capabilities for various samples. These results indicated that the interface could find further utilization in SPR-MS studies especially when physiological conditions were needed.
WOS关键词SERUM-ALBUMIN BINDERS ; ELECTROSPRAY-IONIZATION ; RECENT PROGRESS ; MS/MS SYSTEM ; ION-SOURCE ; PERFORMANCE ; BIOSENSOR ; SAMPLING/IONIZATION ; QUANTIFICATION ; IDENTIFICATION
WOS研究方向Chemistry
语种英语
WOS记录号WOS:000377225600024
出版者ROYAL SOC CHEMISTRY
源URL[http://cas-ir.dicp.ac.cn/handle/321008/170602]  
专题大连化学物理研究所_中国科学院大连化学物理研究所
通讯作者Bai, Yu; Liu, Huwei
作者单位1.Peking Univ, Beijing Natl Lab Mol Sci, Key Lab Bioorgan Chem & Mol Engn, Inst Analyt Chem,Coll Chem & Mol Engn,Minist Educ, Beijing 100871, Peoples R China
2.Ningbo Univ, Res Inst Adv Technol, Ningbo 315211, Zhejiang, Peoples R China
3.Chinese Acad Sci, Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Changchun 130022, Jilin, Peoples R China
4.Jilin Univ, Coll Chem, Changchun 130012, Jilin, Peoples R China
推荐引用方式
GB/T 7714
Zhang, Yiding,Xu, Shuting,Wen, Luhong,et al. A dielectric barrier discharge ionization based interface for online coupling surface plasmon resonance with mass spectrometry[J]. ANALYST,2016,141(11):3343-3348.
APA Zhang, Yiding.,Xu, Shuting.,Wen, Luhong.,Bai, Yu.,Niu, Li.,...&Liu, Huwei.(2016).A dielectric barrier discharge ionization based interface for online coupling surface plasmon resonance with mass spectrometry.ANALYST,141(11),3343-3348.
MLA Zhang, Yiding,et al."A dielectric barrier discharge ionization based interface for online coupling surface plasmon resonance with mass spectrometry".ANALYST 141.11(2016):3343-3348.