Dopant-assisted negative photoionization Ion mobility spectrometry coupled with on-line cooling inlet for real-time monitoring H2S concentration in sewer gas
文献类型:期刊论文
作者 | Peng, Liying1,2; Jiang, Dandan1,2; Wang, Zhenxin1; Hua, Lei1; Li, Haiyang1 |
刊名 | TALANTA |
出版日期 | 2016-06-01 |
卷号 | 153页码:295-300 |
ISSN号 | 0039-9140 |
关键词 | Hydrogen Sulfide Dopant-assisted Negative Photoionization Ion Mobility Spectrometry Semiconductor Cooling Sewer Gas |
DOI | 10.1016/j.talanta.2016.03.041 |
文献子类 | Article |
英文摘要 | Malodorous hydrogen sulfide (H2S) gas often exists in the sewer system and associates with the problems of releasing the dangerous odor to the atmosphere and causing sewer pipe to be corroded. A simple method is in demand for real-time measuring H2S level in the sewer gas. In this paper, an innovated method based on dopant-assisted negative photoionization ion mobility spectrometry (DANP-IMS) with on-line semiconductor cooling inlet was put forward and successfully applied for the real-time measurement of H2S in sewer gas. The influence of moisture was effectively reduced via an on-line cooling method and a non-equilibrium dilution with drift gas. The limits of quantitation for the H2S in >= 60% relative humidity air could be obtained at <= 79.0 ng L-1 with linear ranges of 129-2064 ng L-1. The H2S concentration in a sewer manhole was successfully determined while its product ions were identified by an ion-mobility time-of-fight mass spectrometry. Finally, the correlation between sewer H2S concentration and the daily routines and habits of residents was investigated through hourly or real-time monitoring the variation of sewer H2S in manholes, indicating the power of this DANP-IMS method in assessing the H2S concentration in sewer system. (C) 2016 Elsevier B.V. All rights reserved. |
WOS关键词 | REDUCED SULFUR-COMPOUNDS ; HYDROGEN-SULFIDE ; REACTANT IONS ; AIR ; CHROMATOGRAPHY ; SENSOR ; TEMPERATURE ; EXPLOSIVES ; HEADSPACE ; CORROSION |
WOS研究方向 | Chemistry |
语种 | 英语 |
出版者 | ELSEVIER SCIENCE BV |
WOS记录号 | WOS:000376052900040 |
源URL | [http://cas-ir.dicp.ac.cn/handle/321008/170932] |
专题 | 大连化学物理研究所_中国科学院大连化学物理研究所 |
通讯作者 | Li, Haiyang |
作者单位 | 1.Chinese Acad Sci, Dalian Inst Chem Phys, Key Lab Separat Sci Analyt Chem, Dalian 116023, Peoples R China 2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China |
推荐引用方式 GB/T 7714 | Peng, Liying,Jiang, Dandan,Wang, Zhenxin,et al. Dopant-assisted negative photoionization Ion mobility spectrometry coupled with on-line cooling inlet for real-time monitoring H2S concentration in sewer gas[J]. TALANTA,2016,153:295-300. |
APA | Peng, Liying,Jiang, Dandan,Wang, Zhenxin,Hua, Lei,&Li, Haiyang.(2016).Dopant-assisted negative photoionization Ion mobility spectrometry coupled with on-line cooling inlet for real-time monitoring H2S concentration in sewer gas.TALANTA,153,295-300. |
MLA | Peng, Liying,et al."Dopant-assisted negative photoionization Ion mobility spectrometry coupled with on-line cooling inlet for real-time monitoring H2S concentration in sewer gas".TALANTA 153(2016):295-300. |
入库方式: OAI收割