中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Dopant-assisted negative photoionization Ion mobility spectrometry coupled with on-line cooling inlet for real-time monitoring H2S concentration in sewer gas

文献类型:期刊论文

作者Peng, Liying1,2; Jiang, Dandan1,2; Wang, Zhenxin1; Hua, Lei1; Li, Haiyang1
刊名TALANTA
出版日期2016-06-01
卷号153页码:295-300
ISSN号0039-9140
关键词Hydrogen Sulfide Dopant-assisted Negative Photoionization Ion Mobility Spectrometry Semiconductor Cooling Sewer Gas
DOI10.1016/j.talanta.2016.03.041
文献子类Article
英文摘要Malodorous hydrogen sulfide (H2S) gas often exists in the sewer system and associates with the problems of releasing the dangerous odor to the atmosphere and causing sewer pipe to be corroded. A simple method is in demand for real-time measuring H2S level in the sewer gas. In this paper, an innovated method based on dopant-assisted negative photoionization ion mobility spectrometry (DANP-IMS) with on-line semiconductor cooling inlet was put forward and successfully applied for the real-time measurement of H2S in sewer gas. The influence of moisture was effectively reduced via an on-line cooling method and a non-equilibrium dilution with drift gas. The limits of quantitation for the H2S in >= 60% relative humidity air could be obtained at <= 79.0 ng L-1 with linear ranges of 129-2064 ng L-1. The H2S concentration in a sewer manhole was successfully determined while its product ions were identified by an ion-mobility time-of-fight mass spectrometry. Finally, the correlation between sewer H2S concentration and the daily routines and habits of residents was investigated through hourly or real-time monitoring the variation of sewer H2S in manholes, indicating the power of this DANP-IMS method in assessing the H2S concentration in sewer system. (C) 2016 Elsevier B.V. All rights reserved.
WOS关键词REDUCED SULFUR-COMPOUNDS ; HYDROGEN-SULFIDE ; REACTANT IONS ; AIR ; CHROMATOGRAPHY ; SENSOR ; TEMPERATURE ; EXPLOSIVES ; HEADSPACE ; CORROSION
WOS研究方向Chemistry
语种英语
出版者ELSEVIER SCIENCE BV
WOS记录号WOS:000376052900040
源URL[http://cas-ir.dicp.ac.cn/handle/321008/170932]  
专题大连化学物理研究所_中国科学院大连化学物理研究所
通讯作者Li, Haiyang
作者单位1.Chinese Acad Sci, Dalian Inst Chem Phys, Key Lab Separat Sci Analyt Chem, Dalian 116023, Peoples R China
2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Peng, Liying,Jiang, Dandan,Wang, Zhenxin,et al. Dopant-assisted negative photoionization Ion mobility spectrometry coupled with on-line cooling inlet for real-time monitoring H2S concentration in sewer gas[J]. TALANTA,2016,153:295-300.
APA Peng, Liying,Jiang, Dandan,Wang, Zhenxin,Hua, Lei,&Li, Haiyang.(2016).Dopant-assisted negative photoionization Ion mobility spectrometry coupled with on-line cooling inlet for real-time monitoring H2S concentration in sewer gas.TALANTA,153,295-300.
MLA Peng, Liying,et al."Dopant-assisted negative photoionization Ion mobility spectrometry coupled with on-line cooling inlet for real-time monitoring H2S concentration in sewer gas".TALANTA 153(2016):295-300.

入库方式: OAI收割

来源:大连化学物理研究所

浏览0
下载0
收藏0
其他版本