Momentary Current Test of Enclosed AC Busbar for ITER PF Converter Performed on ITER AC Test Platform
文献类型:期刊论文
作者 | Xia, Minxue; Song, Zhiquan![]() ![]() ![]() |
刊名 | JOURNAL OF FUSION ENERGY
![]() |
出版日期 | 2015-06-01 |
卷号 | 34期号:3页码:552-558 |
关键词 | Isolated phase bus ITER PF converter Momentary current test Test scheme ITER AC test platform |
ISSN号 | 0164-0313 |
DOI | 10.1007/s10894-014-9841-z |
英文摘要 | Isolated phase bus (IPB) is chosen as the structure of the enclosed ac busbar for ITER PF converter, which is used to connect the rectifier transformer and the converter unit of the ITER PF converter module due to its electromagnetic shielding ability. The IPB should withstand huge fault currents, of which the peak value of the current can reach 350 kA, in the worst fault condition according to the design requirement. In order to verify the dynamic stability of the IPB, a momentary current test for ITER PF IPB is necessary. In this paper, the momentary current test of the IPB applied for ITER PF converter based on ITER AC test platform is designed and carried out in detail. The effectiveness of the test scheme is verified by the results of both the simulation and the test. The test scheme presented in this paper is of great value for conducting momentary current tests of electrical equipment with large alternating currents. |
WOS研究方向 | Nuclear Science & Technology |
语种 | 英语 |
WOS记录号 | WOS:000354202200019 |
出版者 | SPRINGER |
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/35234] ![]() |
专题 | 合肥物质科学研究院_中科院等离子体物理研究所 |
通讯作者 | Song, Zhiquan |
作者单位 | Chinese Acad Sci ASIPP, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China |
推荐引用方式 GB/T 7714 | Xia, Minxue,Song, Zhiquan,Li, Jinchao,et al. Momentary Current Test of Enclosed AC Busbar for ITER PF Converter Performed on ITER AC Test Platform[J]. JOURNAL OF FUSION ENERGY,2015,34(3):552-558. |
APA | Xia, Minxue,Song, Zhiquan,Li, Jinchao,&Fu, Peng.(2015).Momentary Current Test of Enclosed AC Busbar for ITER PF Converter Performed on ITER AC Test Platform.JOURNAL OF FUSION ENERGY,34(3),552-558. |
MLA | Xia, Minxue,et al."Momentary Current Test of Enclosed AC Busbar for ITER PF Converter Performed on ITER AC Test Platform".JOURNAL OF FUSION ENERGY 34.3(2015):552-558. |
入库方式: OAI收割
来源:合肥物质科学研究院
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。