中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Rapid detection of taste and odor compounds in water using the newly invented chemi-ionization technique coupled with time-of-flight mass spectrometry

文献类型:期刊论文

作者Ma, Pengkun; Yang, Bo; Shu, Jinian; Zhang, Haixu; Huang, Jingyun
刊名ANALYTICA CHIMICA ACTA
出版日期2018-12-04
卷号1035页码:119-128
ISSN号0003-2670
关键词On-line detection Odorant Water Chemi-ionization Mass spectrometry
文献子类Article
英文摘要Taste and odor (T&O) compounds are widespread in water environments and have attracted considerable public attention. Nowadays, the standard detections of these chemicals rely mainly on off-line methods such as GC-MS or evaluation by trained analysts' senses. In this study, we report a method for the rapid detection of T&O compounds in water by exploiting a newly invented chemi-ionization source, in combination with headspace vapor measurement at room temperature. The calibrated limits of detection (LODs) of 2-methylbutyraldehyde, methyl tert-butyl ether (MTBE), methyl methacrylate (MMA), 2-isobutyl-3-methyoxypyrazine (IBMP), and 2-isopropyl-3-methoxypyrazine (IPMP) are in the range of 3.5-50.2 ng L-1, and the estimated LODs of 2-methylisoborneol (2-MIB) and geosmin (GSM) are 0.25 and 0.77 ng L-1, respectively. The calibration results reveal that the instrumental LODs for 2-methylbutyraldehyde, MTBE, MMA, beta-cyclocitral, 2-MIB, and GSM are 1-2 orders of magnitude better than the odor thresholds of humans. The accuracy, precision, recovery, and linearity (R-2) of the method are tested. Water samples from city tap water and three rivers in Beijing are assessed using this technique, and the typical T&O compositions are observed with concentrations ranging from 0.2 to 297 ng L-1. The new ultra-sensitive rapid detection method shows comparable sensitivities to the existing off-line technique and displays great potential for real-time detection of T&O pollution in water environments. (c) 2018 Elsevier B.V. All rights reserved.
源URL[http://ir.rcees.ac.cn/handle/311016/41172]  
专题生态环境研究中心_环境水质学国家重点实验室
推荐引用方式
GB/T 7714
Ma, Pengkun,Yang, Bo,Shu, Jinian,et al. Rapid detection of taste and odor compounds in water using the newly invented chemi-ionization technique coupled with time-of-flight mass spectrometry[J]. ANALYTICA CHIMICA ACTA,2018,1035:119-128.
APA Ma, Pengkun,Yang, Bo,Shu, Jinian,Zhang, Haixu,&Huang, Jingyun.(2018).Rapid detection of taste and odor compounds in water using the newly invented chemi-ionization technique coupled with time-of-flight mass spectrometry.ANALYTICA CHIMICA ACTA,1035,119-128.
MLA Ma, Pengkun,et al."Rapid detection of taste and odor compounds in water using the newly invented chemi-ionization technique coupled with time-of-flight mass spectrometry".ANALYTICA CHIMICA ACTA 1035(2018):119-128.

入库方式: OAI收割

来源:生态环境研究中心

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。