中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
The differences between the measured heat flow and BSR heat flow in the Shenhu gas hydrate drilling area, northern South China Sea

文献类型:期刊论文

作者Zhang, Jian4; Wu, Shi-Guo2,3,4; Dong, Miao4; Xu, Xing1
刊名ENERGY EXPLORATION & EXPLOITATION
出版日期2019-03-01
卷号37期号:2页码:756-769
关键词Gas Hydrate Heat Flow Bottom Simulating Reflector Topographic Effects Fluid Flux
ISSN号0144-5987
DOI10.1177/0144598718793907
英文摘要

Temperature is an important factor that affects the stability of a gas hydrate. To investigate the geothermal characteristics in the gas hydrate drilling area, heat flow measurements were performed in the surrounding area of the SH2 well. The measured heat flow was compared with the bottom simulating reflector heat flow, which was calculated by using the depth of the bottom simulating reflector in the seismic data. Combined with the geological background of the Shenhu drilling area, we analyzed the reasons for the differences between the measured heat flow and the bottom simulating reflector heat flow. In addition to analyzing the differences caused by the calculation parameters, we calculated the 3-D topographic effects on the measured heat flow by using the finite element numerical simulation method. The results show that the measured heat flow was seriously affected by the topography and produced a -50-30% error in the study area. After terrain correction of the measured heat flow, we found that the data were greater than the bottom simulating reflector heat flow at almost all sites. Therefore, we considered the impact of fluid activity and calculated the relationship among the thickness of the gas hydrate stability zone, the fluid flux and the heat flow. The results show that when the base of the bottom simulating reflector was at a certain depth, the geothermal gradient increased with the increasing upward migration of the fluid flux. Therefore, when upward fluid migration is present, the measured heat flow in the seafloor sediments is greater than the heat flow in the deep layers. In general, we showed that the influences of the topography and fluid activity are the main factors leading to the inconsistency between the bottom simulating reflector heat flow and the measured heat flow in the Shenhu gas hydrate drilling area.

WOS关键词Bottom-simulating Reflectors ; Methane Hydrate ; Accretionary Prism ; Stability
资助项目National Natural Science Foundation of China[41574074] ; National Natural Science Foundation of China[U1701245] ; National Natural Science Foundation of China[41430319]
WOS研究方向Energy & Fuels
语种英语
WOS记录号WOS:000461562900010
出版者SAGE PUBLICATIONS INC
资助机构National Natural Science Foundation of China
版本出版稿
源URL[http://ir.idsse.ac.cn/handle/183446/6606]  
专题深海科学研究部_深海地球物理与资源研究室
通讯作者Zhang, Jian
作者单位1.Guangzhou Marine Geol Survey, Guangzhou, Guangdong, Peoples R China
2.Qingdao Natl Lab Marine Sci & Technol, Qingdao, Peoples R China
3.Chinese Acad Sci, Inst Deep Sea Sci & Engn, Lab Marine Geophys & Georesources, Sanya, Peoples R China
4.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Zhang, Jian,Wu, Shi-Guo,Dong, Miao,et al. The differences between the measured heat flow and BSR heat flow in the Shenhu gas hydrate drilling area, northern South China Sea[J]. ENERGY EXPLORATION & EXPLOITATION,2019,37(2):756-769.
APA Zhang, Jian,Wu, Shi-Guo,Dong, Miao,&Xu, Xing.(2019).The differences between the measured heat flow and BSR heat flow in the Shenhu gas hydrate drilling area, northern South China Sea.ENERGY EXPLORATION & EXPLOITATION,37(2),756-769.
MLA Zhang, Jian,et al."The differences between the measured heat flow and BSR heat flow in the Shenhu gas hydrate drilling area, northern South China Sea".ENERGY EXPLORATION & EXPLOITATION 37.2(2019):756-769.

入库方式: OAI收割

来源:深海科学与工程研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。