中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Rationally Designed Fluorescence (OH)-O-center dot Probe with High Sensitivity and Selectivity for Monitoring the Generation of (OH)-O-center dot in Iron Autoxidation without Addition of H2O2

文献类型:期刊论文

作者Li, Hongyu1,2; Li, Xiaohua1; Shi, Wen1; Xu, Yanhui1; Ma, Huimin1,2
刊名ANGEWANDTE CHEMIE-INTERNATIONAL EDITION
出版日期2018-09-24
卷号57期号:39页码:12830-12834
关键词Analytical Methods Fluorescent Probes Hydroxyl Radicals Iron Autoxidation
ISSN号1433-7851
DOI10.1002/anie.201808400
英文摘要The first sensitive fluorescence (OH)-O-center dot probe (1) that is capable of monitoring the generation of trace (OH)-O-center dot in iron autoxidation is presented. The probe 1 was designed by utilizing both the unique aromatic hydroxylation and the electrophilicity of (OH)-O-center dot, and prepared by incorporating a strong electron-donating methoxy group into a cyanine fluorochrome to enhance the trapping ability for (OH)-O-center dot. Reaction of 1 with (OH)-O-center dot leads to a larger pi-conjugation formation and near-infrared fluorescence off-on response. The capability of probe 1 has been demonstrated by imaging (OH)-O-center dot generated in living cells under iron autoxidation as well as various stimuli, which reveals that the basal level of (OH)-O-center dot in RAW 264.7 cells is lower than that in HeLa cells. The superior analytical performance of probe 1 makes it useful for detecting trace (OH)-O-center dot in some critical physiological and pathological processes associated with iron autoxidation.
语种英语
WOS记录号WOS:000444941600039
出版者WILEY-V C H VERLAG GMBH
源URL[http://ir.iccas.ac.cn/handle/121111/43067]  
专题中国科学院化学研究所
通讯作者Li, Xiaohua; Shi, Wen; Ma, Huimin
作者单位1.Chinese Acad Sci, Inst Chem, Key Lab Analyt Chem Living Biosyst, Beijing Natl Lab Mol Sci, Beijing 100190, Peoples R China
2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Li, Hongyu,Li, Xiaohua,Shi, Wen,et al. Rationally Designed Fluorescence (OH)-O-center dot Probe with High Sensitivity and Selectivity for Monitoring the Generation of (OH)-O-center dot in Iron Autoxidation without Addition of H2O2[J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION,2018,57(39):12830-12834.
APA Li, Hongyu,Li, Xiaohua,Shi, Wen,Xu, Yanhui,&Ma, Huimin.(2018).Rationally Designed Fluorescence (OH)-O-center dot Probe with High Sensitivity and Selectivity for Monitoring the Generation of (OH)-O-center dot in Iron Autoxidation without Addition of H2O2.ANGEWANDTE CHEMIE-INTERNATIONAL EDITION,57(39),12830-12834.
MLA Li, Hongyu,et al."Rationally Designed Fluorescence (OH)-O-center dot Probe with High Sensitivity and Selectivity for Monitoring the Generation of (OH)-O-center dot in Iron Autoxidation without Addition of H2O2".ANGEWANDTE CHEMIE-INTERNATIONAL EDITION 57.39(2018):12830-12834.

入库方式: OAI收割

来源:化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。