中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Differential detection of Rhizoma coptidis by capillary electrophoresis electrospray ionization mass spectrometry with a nanospray interface

文献类型:期刊论文

作者Liu, Jing-Xin1; Zhang, Yi-Wei1; Yuan, Fang1; Chen, Hong-Xu2; Zhang, Xin-Xiang1
刊名ELECTROPHORESIS
出版日期2014-11-01
卷号35期号:21-22页码:3258-3263
关键词Ce-nanospary-ms Pca Rhizoma Coptidis Tcm
ISSN号0173-0835
DOI10.1002/elps.201400334
英文摘要A lab prototype CE-nanospray-MS platform with a high sensitivity porous sprayer was successfully applied in differential identification of Rhizoma coptidis in this paper. To obtain a stable and reliable nanospray, detailed optimizations about emitter geometry, buffer composition, emitter position, and spray voltage, as well as emitter cleanliness were discussed. Results showed that the reproducibility and sensitivity for separations of alkaloid standards were satisfactory using CE-nanospray-MS, which were also compared to ultra-HPLC (UHPLC)-MS. Their signal responds were at the same order of magnitude (intensities: 0.8 - 1.5 x 10(8) vs. 3.8 - 6.2 x 10(8)), even though a 2 nL injection for CE was 2500-fold lower than UHPLC (5 mu L injection). The absolute LOD results of CE-MS showed a remarkable superiority (18-24 fg), equal to 1000-fold lower than that of UHPLC-MS. Principal component analysis (PCA) of adulterated R. coptidis showed that this protocol had the ability to profile and qualify complex herb medicines, which also created a great potential for evaluation and qualification of rare and valuable Chinese medicines in future.
语种英语
WOS记录号WOS:000345272200030
出版者WILEY-BLACKWELL
源URL[http://ir.iccas.ac.cn/handle/121111/52987]  
专题中国科学院化学研究所
通讯作者Zhang, Xin-Xiang
作者单位1.Peking Univ, Coll Chem, BNLMS, Key Lab Bioorgan Chem & Mol Engn,Minist Educ,Inst, Beijing 100871, Peoples R China
2.Shanghai AB Sciex Analyt Instrument Trading Co Lt, Beijing, Peoples R China
推荐引用方式
GB/T 7714
Liu, Jing-Xin,Zhang, Yi-Wei,Yuan, Fang,et al. Differential detection of Rhizoma coptidis by capillary electrophoresis electrospray ionization mass spectrometry with a nanospray interface[J]. ELECTROPHORESIS,2014,35(21-22):3258-3263.
APA Liu, Jing-Xin,Zhang, Yi-Wei,Yuan, Fang,Chen, Hong-Xu,&Zhang, Xin-Xiang.(2014).Differential detection of Rhizoma coptidis by capillary electrophoresis electrospray ionization mass spectrometry with a nanospray interface.ELECTROPHORESIS,35(21-22),3258-3263.
MLA Liu, Jing-Xin,et al."Differential detection of Rhizoma coptidis by capillary electrophoresis electrospray ionization mass spectrometry with a nanospray interface".ELECTROPHORESIS 35.21-22(2014):3258-3263.

入库方式: OAI收割

来源:化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。