Induced Dual-Nanospray: A Novel Internal Calibration Method for Convenient and Accurate Mass Measurement
文献类型:期刊论文
作者 | Li, Yafeng1,2; Zhang, Ning1,2; Zhou, Yueming1,2; Wang, Jianing1,2; Zhang, Yiming3; Wang, Jiyun1,2; Xiong, Caiqiao1,2; Chen, Suming1,2; Nie, Zongxiu1,2,4 |
刊名 | JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY
![]() |
出版日期 | 2013-09-01 |
卷号 | 24期号:9页码:1446-1449 |
关键词 | Internal Calibration Induced Nanospray Alternating Current Mass Spectrometry |
ISSN号 | 1044-0305 |
DOI | 10.1007/s13361-013-0670-5 |
英文摘要 | Accurate mass information is of great importance in the determination of unknown compounds. An effective and easy-to-control internal mass calibration method will dramatically benefit accurate mass measurement. Here we reported a simple induced dual-nanospray internal calibration device which has the following three advantages: (1) the two sprayers are in the same alternating current field; thus both reference ions and sample ions can be simultaneously generated and recorded. (2) It is very simple and can be easily assembled. Just two metal tubes, two nanosprayers, and an alternating current power supply are included. (3) With the low-flow-rate character and the versatility of nanoESI, this calibration method is capable of calibrating various samples, even untreated complex samples such as urine and other biological samples with small sample volumes. The calibration errors are around 1 ppm in positive ion mode and 3 ppm in negative ion mode with good repeatability. This new internal calibration method opens up new possibilities in the determination of unknown compounds, and it has great potential for the broad applications in biological and chemical analysis. |
语种 | 英语 |
WOS记录号 | WOS:000323060000017 |
出版者 | SPRINGER |
源URL | [http://ir.iccas.ac.cn/handle/121111/54779] ![]() |
专题 | 中国科学院化学研究所 |
通讯作者 | Nie, Zongxiu |
作者单位 | 1.Chinese Acad Sci, Inst Chem, Key Lab Analyt Chem Living Biosyst, Beijing 100080, Peoples R China 2.Beijing Natl Lab Mol Sci, Beijing, Peoples R China 3.Jiangsu Skyray Instrument Co Ltd, Kunshan, Jiangsu, Peoples R China 4.Beijing Ctr Mass Spectrometry, Beijing, Peoples R China |
推荐引用方式 GB/T 7714 | Li, Yafeng,Zhang, Ning,Zhou, Yueming,et al. Induced Dual-Nanospray: A Novel Internal Calibration Method for Convenient and Accurate Mass Measurement[J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY,2013,24(9):1446-1449. |
APA | Li, Yafeng.,Zhang, Ning.,Zhou, Yueming.,Wang, Jianing.,Zhang, Yiming.,...&Nie, Zongxiu.(2013).Induced Dual-Nanospray: A Novel Internal Calibration Method for Convenient and Accurate Mass Measurement.JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY,24(9),1446-1449. |
MLA | Li, Yafeng,et al."Induced Dual-Nanospray: A Novel Internal Calibration Method for Convenient and Accurate Mass Measurement".JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 24.9(2013):1446-1449. |