Incorporation of flow injection analysis or capillary electrophoresis with resonance Rayleigh scattering detection for inorganic ion analysis
文献类型:期刊论文
作者 | Qi, L; Han, ZQ; Chen, Y |
刊名 | JOURNAL OF CHROMATOGRAPHY A
![]() |
出版日期 | 2006-03-31 |
卷号 | 1110期号:1-2页码:235-239 |
关键词 | Resonance Rayleigh Scattering Detection Capillary Electrophoresis Flow Injection Analysis Iodide Basic Rhodamine b Dye Permanganate Dichromate |
ISSN号 | 0021-9673 |
DOI | 10.1016/j.chroma.2006.01.053 |
英文摘要 | Resonance Rayleigh scattering (RRS) has been explored as a detection (RRSD) technique for capillary electrophoresis (CE) or flow injection analysis (FIA) of inorganic ions. The detection was achieved through a scattering probe of ion-association complex formed from rhodamine B (Rh B) and iodine. The probe scatters strongly at 630 nm when oxidants such as Cr2O72-, MnO4- and ClO- present in a mixed solution of Rh B and iodide. The scattering disappears once iodine is reduced by reductants. Oxidant or reductant species in a sample can thus be detected by positive or negative RRS signal. To verify the RRSD, FIA-RRSD was first constructed and continuous measurement of testing samples containing Cr2O72-, MnO4- and/or ClO- was performed. The detection limits reached a level of decade nM and a linear range was found between peak height and concentration at the range of 0.255-2.04 mu M for Cr2O72-, 0.158-3.16 mu M for MnO4-, and 1.18-9.43 mu M for ClO-, with linear regression coefficients of all above 0.99. The run-to-run relative standard deviation of peak height was less than 3% (n = 6). CE-RRSD was then set up and studied, using a capillary of 75 mu m i.d. x 33 cm filled with a running buffer of 50 mM citrate and 25 mM Tris (pH 3.32) and worked under -12 kV at room temperature. The CE eluent was at-line conducted into a stream of rhodamine B and iodine flowing inner a wide tube by plugging the capillary outlet into the wide tube. Different mixtures prepared from Cr2O72-, MnO4- and ClO- were successfully separated and detected by the CE-RRSD. (c) 2006 Elsevier B.V. All rights reserved. |
语种 | 英语 |
WOS记录号 | WOS:000236439000030 |
出版者 | ELSEVIER SCIENCE BV |
源URL | [http://ir.iccas.ac.cn/handle/121111/58321] ![]() |
专题 | 中国科学院化学研究所 |
通讯作者 | Chen, Y |
作者单位 | 1.Chinese Acad Sci, Lab Analyt Chem Life Sci, Dept Biol Chem, Inst Chem, Beijing 100080, Peoples R China 2.Chinese Acad Sci, Grad Sch, Beijing 100039, Peoples R China |
推荐引用方式 GB/T 7714 | Qi, L,Han, ZQ,Chen, Y. Incorporation of flow injection analysis or capillary electrophoresis with resonance Rayleigh scattering detection for inorganic ion analysis[J]. JOURNAL OF CHROMATOGRAPHY A,2006,1110(1-2):235-239. |
APA | Qi, L,Han, ZQ,&Chen, Y.(2006).Incorporation of flow injection analysis or capillary electrophoresis with resonance Rayleigh scattering detection for inorganic ion analysis.JOURNAL OF CHROMATOGRAPHY A,1110(1-2),235-239. |
MLA | Qi, L,et al."Incorporation of flow injection analysis or capillary electrophoresis with resonance Rayleigh scattering detection for inorganic ion analysis".JOURNAL OF CHROMATOGRAPHY A 1110.1-2(2006):235-239. |
入库方式: OAI收割
来源:化学研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。