Quartz crystal microbalance biosensor for recombinant human interferon-beta detection based on antisense peptide approach
文献类型:期刊论文
作者 | Luo, Jia; Zhang, Qundan; Huang, Yanyan; Liu, Guoquan; Zhao, Rui |
刊名 | ANALYTICA CHIMICA ACTA
![]() |
出版日期 | 2007-05-02 |
卷号 | 590期号:1页码:91-97 |
关键词 | Quartz Crystal Microbalance Biosensor Antisense Peptide Recombinant Human Interferon-p Flow Injection Analysis |
ISSN号 | 0003-2670 |
DOI | 10.1016/j.aca.2007.03.022 |
英文摘要 | Quartz crystal microbalance (QCM) biosensors for recombinant human interferon-beta (rhIFN-beta) were constructed by utilizing antisense peptides adhering to the QCM gold surfaces. Two antisense peptides, both corresponding to the N-terminal fragment 1-14 of rhIFN-beta, were used in this study. Antisense peptide AS-1 was the original antisense peptide and AS-2 was the modified antisense peptide based on the antisense peptide degeneracy. Both antisense peptides were immobilized on the gold electrodes of piezoelectric crystals, respectively, via a self-assembling monolayer of 1,2-ethanedithiol. The binding affinity between rhIFN-beta and each immobilized antisense peptide in solution was evaluated using a quartz crystal microbalance-flow injection analysis (QCM-FIA) system. The dissociation constant of rhIFN-beta on the antisense peptide AS-1 and AS-2 biosensor was (1.89 +/- 0.101) X 10(-4) and (1.22 +/- 0.0479) x 10(-5) mol L-1, respectively. The results suggested that AS-2 had a higher binding affinity to rhIFN-beta than AS-1. The detection for rhIFN-beta using each biosensor was precise and reproducible. The linear response ranges of rhIFN-beta binding to both biosensors were same with a concentration range of 0.12-0.96 mg mL(-1). The results demonstrated the successful construction of highly selective QCM biosensors using antisense peptide approach, and also confirmed the feasibility of increasing antisense peptide binding affinity by appropriate sequence modification. (c) 2007 Elsevier B.V. All rights reserved. |
语种 | 英语 |
WOS记录号 | WOS:000246098400011 |
出版者 | ELSEVIER SCIENCE BV |
源URL | [http://ir.iccas.ac.cn/handle/121111/61681] ![]() |
专题 | 中国科学院化学研究所 |
通讯作者 | Luo, Jia |
作者单位 | Chinese Acad Sci, Inst Chem, Lab Analyt Chem Life Sci, Beijing Natl Lab Mol Sci, Beijing 100080, Peoples R China |
推荐引用方式 GB/T 7714 | Luo, Jia,Zhang, Qundan,Huang, Yanyan,et al. Quartz crystal microbalance biosensor for recombinant human interferon-beta detection based on antisense peptide approach[J]. ANALYTICA CHIMICA ACTA,2007,590(1):91-97. |
APA | Luo, Jia,Zhang, Qundan,Huang, Yanyan,Liu, Guoquan,&Zhao, Rui.(2007).Quartz crystal microbalance biosensor for recombinant human interferon-beta detection based on antisense peptide approach.ANALYTICA CHIMICA ACTA,590(1),91-97. |
MLA | Luo, Jia,et al."Quartz crystal microbalance biosensor for recombinant human interferon-beta detection based on antisense peptide approach".ANALYTICA CHIMICA ACTA 590.1(2007):91-97. |
入库方式: OAI收割
来源:化学研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。