A weak cation monolithic column for enrichment and determination of ranitidine hydrochloride in human urine

文献类型:期刊论文

作者Zhu Tao1,2; Yang Geng-Liang1,2,3; Jiang Ming-Ming1,2; Cao Wei-Min1,2
刊名CHINESE JOURNAL OF ANALYTICAL CHEMISTRY
出版日期2008-07-01
卷号36期号:7页码:895-899
关键词Weak Cation Monolithic Column On-line Solid Phase Extraction Column Switch Urine Sample Ranitidine Hydrochloride
ISSN号0253-3820
英文摘要A weak cation exchange monolithic column was prepared in stainless steel column tubule, which was used for analysis and determination of ranitidine hydrochloride as solid phase extraction (SPE) material in urine samples. With the column switch technique, online cleaning up and screening of human urine sample was executed under the condition of 2.5 mmol/L K2HPO4 solutions. Chromatographic operation was performed by reversed-phase HPLC on a C-18 column with 1.0 mL/min flow ratio and ultraviolet detection at 320 nm, using an eluting solution consisting of methanol-2. 5 mmol/L K2HPO4 (2: 1, V/V). Results showed that there was a good linear relationship between the response and the concentration of ranitidine hydrochloride within the range of 0.05 - 5.0 mg/L (r = 0. 9994, n = 7). The absolutely recovery rate was from 75.0% to 85.0% and the detection limit was 0. 01 mg/L. The inter-day RSD and intra-day RSD were less than 5%. This method was suitable for the determination of Ranitidine hydrochloride in human urine, which had avoided tedious pretreatment and provided a fast, economic, repeated and effective method for assaying trace drugs in biologic samples.
语种英语
WOS记录号WOS:000258939700006
出版者ELSEVIER SCIENCE INC
源URL[http://ir.iccas.ac.cn/handle/121111/64345]  
专题中国科学院化学研究所
通讯作者Yang Geng-Liang
作者单位1.Hebei Univ, Coll Pharm, Baoding 071002, Peoples R China
2.Hebei Prov Key Lab Med Qual Res, Baoding 071002, Peoples R China
3.Chinese Acad Sci, Inst Chem, Ctr Mol Sci, Beijing 100080, Peoples R China
推荐引用方式
GB/T 7714
Zhu Tao,Yang Geng-Liang,Jiang Ming-Ming,et al. A weak cation monolithic column for enrichment and determination of ranitidine hydrochloride in human urine[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2008,36(7):895-899.
APA Zhu Tao,Yang Geng-Liang,Jiang Ming-Ming,&Cao Wei-Min.(2008).A weak cation monolithic column for enrichment and determination of ranitidine hydrochloride in human urine.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,36(7),895-899.
MLA Zhu Tao,et al."A weak cation monolithic column for enrichment and determination of ranitidine hydrochloride in human urine".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 36.7(2008):895-899.

入库方式: OAI收割

来源:化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。