Phage M13KO7 detection with biosensor based on imaging ellipsometry and AFM microscopic confirmation

文献类型:期刊论文

作者Qi, Cai1,3,4; Lin, Yi2,5; Feng, Jing3; Wang, Zhan-Hui1; Zhu, Chuan-Feng2; Meng, Yong-Hong1; Yan, Xi-Yun3; Wan, Li-Jun2; Jin, Gang1,3
刊名VIRUS RESEARCH
出版日期2009-03-01
卷号140期号:1-2页码:79-84
关键词Phage Detection Imaging Ellipsometry Microarray Atomic Force Microscope Microfluidic Surface Modification
ISSN号0168-1702
DOI10.1016/j.virusres.2008.11.010
英文摘要A rapid detection and identification of pathogens is important for minimizing transfer and spread of disease. A label-free and multiplex biosensor based on imaging ellipsometry (BIE) had been developed for the detection of phage M13KO7. The surface of silicon wafer is modified with aldehyde, and proteins can be patterned homogeneously and simultaneously on the surface of silicon wafer in an array format by a microfluidic system. Avidin is immobilized on the surface for biotin-anti-M13 immobilization by means of interaction between avidin and biotin, which will serve as ligand against phage M13KO7. Phages M13KO7 are specifically captured by the ligand when phage M13KO7 solution passes over the surface, resulting in a significant increase of mass surface concentration of the anti-M13 binding phage M13KO7 layer, which could be detected by imaging ellipsometry with a sensitivity of 10(9) pfu/ml. Moreover, atomic force microscopy is also used to confirm the fact that phage M13KO7 has been directly captured by ligands on the surface. It indicates that BIE is competent for direct detection of phage M13KO7 and has potential in the field of virus detection. (C) 2008 Elsevier B.V. All rights reserved.
语种英语
WOS记录号WOS:000264650600011
出版者ELSEVIER SCIENCE BV
源URL[http://ir.iccas.ac.cn/handle/121111/66365]  
专题中国科学院化学研究所
通讯作者Jin, Gang
作者单位1.Chinese Acad Sci, Inst Mech, Beijing 100190, Peoples R China
2.Chinese Acad Sci, Inst Chem, Beijing 100190, Peoples R China
3.Chinese Acad Sci, Inst Biophys, Beijing 100101, Peoples R China
4.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
5.Wuhan Univ, Coll Chem & Mol Sci, Wuhan 430072, Peoples R China
推荐引用方式
GB/T 7714
Qi, Cai,Lin, Yi,Feng, Jing,et al. Phage M13KO7 detection with biosensor based on imaging ellipsometry and AFM microscopic confirmation[J]. VIRUS RESEARCH,2009,140(1-2):79-84.
APA Qi, Cai.,Lin, Yi.,Feng, Jing.,Wang, Zhan-Hui.,Zhu, Chuan-Feng.,...&Jin, Gang.(2009).Phage M13KO7 detection with biosensor based on imaging ellipsometry and AFM microscopic confirmation.VIRUS RESEARCH,140(1-2),79-84.
MLA Qi, Cai,et al."Phage M13KO7 detection with biosensor based on imaging ellipsometry and AFM microscopic confirmation".VIRUS RESEARCH 140.1-2(2009):79-84.

入库方式: OAI收割

来源:化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。