Performance of vanadium redox flow battery with a novel amphoteric ion exchange membrane synthesized by two-step grafting method
文献类型:期刊论文
作者 | Qiu, Jingyi1; Zhai, Maolin1; Chen, Jinhua2; Wang, Yu1; Peng, Jing1; Xu, Ling1; Li, Jiuqiang1; Wei, Genshuan1 |
刊名 | JOURNAL OF MEMBRANE SCIENCE
![]() |
出版日期 | 2009-10-15 |
卷号 | 342期号:1-2页码:215-220 |
关键词 | Vanadium Redox Flow Battery Two-step Radiation Grafting Amphoteric Ion Exchange Membrane |
ISSN号 | 0376-7388 |
DOI | 10.1016/j.memsci.2009.06.043 |
英文摘要 | A novel ETFE-based amphoteric ion exchange membrane (AIEM) was prepared through a two-step radiation-induced grafting technique. ETFE film was first grafted with styrene (St) (denoted as ETFE-g-PS), followed with a sulfonation treatment to obtain a cation exchange membrane (ETFE-g-PSSA). The ETFE-g-PSSA membrane was subsequently grafted with dimethylaminoethyl methacrylate (DMAEMA) and then protonated, resulting in an AIEM with both anionic and cationic groups. The grafting yields (GY) in the above two steps increased with absorbed dose and leveled off at about 30 kGy and 20 kGy, respectively. Micro-FTIR and XPS analyses testified that the AIEM had been prepared as designed. The obtained AIEM exhibited high ion exchange capacity (IEC) and conductivity, as well as significantly reduced permeability of vanadium ions. Vanadium redox flow battery (VRFB) assembled with the AIEM maintained an open circuit voltage (OCV) higher than 1.3 V after placed for 300 h, and exhibited higher columbic efficiency and energy efficiency than that with Nafion 117 membrane. (C) 2009 Elsevier B.V. All rights reserved. |
语种 | 英语 |
WOS记录号 | WOS:000269678400026 |
出版者 | ELSEVIER SCIENCE BV |
源URL | [http://ir.iccas.ac.cn/handle/121111/66487] ![]() |
专题 | 中国科学院化学研究所 |
通讯作者 | Zhai, Maolin |
作者单位 | 1.Peking Univ, BNLMS, Dept Appl Chem, Coll Chem & Mol Engn, Beijing 100871, Peoples R China 2.Japan Atom Energy Agcy, Conducting Polymer Mat Grp, Environm & Ind Mat Res Div, Quantum Beam Sci Directorate, Takasaki, Gumma 3701292, Japan |
推荐引用方式 GB/T 7714 | Qiu, Jingyi,Zhai, Maolin,Chen, Jinhua,et al. Performance of vanadium redox flow battery with a novel amphoteric ion exchange membrane synthesized by two-step grafting method[J]. JOURNAL OF MEMBRANE SCIENCE,2009,342(1-2):215-220. |
APA | Qiu, Jingyi.,Zhai, Maolin.,Chen, Jinhua.,Wang, Yu.,Peng, Jing.,...&Wei, Genshuan.(2009).Performance of vanadium redox flow battery with a novel amphoteric ion exchange membrane synthesized by two-step grafting method.JOURNAL OF MEMBRANE SCIENCE,342(1-2),215-220. |
MLA | Qiu, Jingyi,et al."Performance of vanadium redox flow battery with a novel amphoteric ion exchange membrane synthesized by two-step grafting method".JOURNAL OF MEMBRANE SCIENCE 342.1-2(2009):215-220. |
入库方式: OAI收割
来源:化学研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。