中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Rapid and sensitive detection of microcystin by immunosensor based on nuclear magnetic resonance

文献类型:期刊论文

作者Ma, Wei1; Chen, Wei1; Qiao, Ruirui2; Liu, Chunyan2; Yang, Chunhui2; Li, Zhuokun1; Xu, Dinghua1; Peng, Chifang1; Jin, Zhengyu1; Xu, Chuanlai1
刊名BIOSENSORS & BIOELECTRONICS
出版日期2009-09-15
卷号25期号:1页码:240-243
关键词Detection Microcystin Immunosensor Nuclear Magnetic Resonance Sensitive Magnetic Nanoparticles
ISSN号0956-5663
DOI10.1016/j.bios.2009.06.020
英文摘要A stable and sensitive toxin residues immunosensor based on the relaxation of magnetic nanoparticles was developed. The method was performed in one reaction and offered sensitive, fast detection of target toxin residues in water. The target analyte, microcystin-LR (MC-LR) in Tai lake water, competed with the antigens on the surface of the magnetic nanoparticles and then influenced the formation of aggregates of the magnetic nanoparticles. Accordingly, the magnetic relaxation time of the magnetic nanoparticles was changed under the effect of the target analyte. The calibration curve was deduced at different concentrations of the target analyte. The limit of detection (LOD) of MC-LR was 0.6 ng g(-1) and the detection range was 1-18 ng g(-1). Another important feature of the developed method was the easy operation: only two steps were needed (1) to mix the magnetic nanoparticle solution with the sample solution and (2) read the results through the instrument. Therefore, the developed method may be a useful tool for toxin residues sensing and may find widespread applications. (C) 2009 Elsevier B.V. All rights reserved.
语种英语
WOS记录号WOS:000270538400039
出版者ELSEVIER ADVANCED TECHNOLOGY
源URL[http://ir.iccas.ac.cn/handle/121111/67883]  
专题中国科学院化学研究所
通讯作者Xu, Chuanlai
作者单位1.Jiangnan Univ, Sch Food Sci & Technol, Wuxi 214122, Jiangsu Prov, Peoples R China
2.Chinese Acad Sci, Inst Chem, Beijing 10008, Peoples R China
推荐引用方式
GB/T 7714
Ma, Wei,Chen, Wei,Qiao, Ruirui,et al. Rapid and sensitive detection of microcystin by immunosensor based on nuclear magnetic resonance[J]. BIOSENSORS & BIOELECTRONICS,2009,25(1):240-243.
APA Ma, Wei.,Chen, Wei.,Qiao, Ruirui.,Liu, Chunyan.,Yang, Chunhui.,...&Wang, Libing.(2009).Rapid and sensitive detection of microcystin by immunosensor based on nuclear magnetic resonance.BIOSENSORS & BIOELECTRONICS,25(1),240-243.
MLA Ma, Wei,et al."Rapid and sensitive detection of microcystin by immunosensor based on nuclear magnetic resonance".BIOSENSORS & BIOELECTRONICS 25.1(2009):240-243.

入库方式: OAI收割

来源:化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。