Instrument compliance effects revisited: linear viscoelastic measurements

文献类型:期刊论文

作者Liu, Chen-Yang1,2; Yao, Minglong3; Garritano, Ronald G.3; Franck, Aloyse J.4; Bailly, Christian2
刊名RHEOLOGICA ACTA
出版日期2011-06-01
卷号50期号:5-6页码:537-546
关键词Compliance Dynamic Moduli Viscoelasticity Rheometer
ISSN号0035-4511
DOI10.1007/s00397-011-0560-3
英文摘要Torsional compliance of the torque transducer can be an important issue in linear viscoelastic (LVE) measurements when the sample stiffness is high relative to the instrument stiffness. We evaluated compliance effects of the ARES 2K-FRT on LVE measurements by systematically comparing the results of the frequency sweep mode obtained with 25 and 8 mm plates, respectively. In addition to the transducer, the test fixtures do contribute significantly to the system compliance. Without correction, the upper limit for the complex modulus vertical bar G*vertical bar is approximately close to 4 x 10(5) Pa at 10% uncertainty, when using 25 mm plates. This limit is lower than the plateau modulus (G(N)(0)) ofof most polymers. Therefore, instrument compliance can lead to significant errors for G(N)(0) and wrong scaling for G '' in the plateau and Rouse regions. The respective roles of transducer and tool compliances are discussed. The FRT transducer compliance is corrected in real time in the instrument firmware. Tool compliance is a common problem for all rheometers when measuring stiff samples.
语种英语
WOS记录号WOS:000296515600010
出版者SPRINGER
源URL[http://ir.iccas.ac.cn/handle/121111/73677]  
专题中国科学院化学研究所
通讯作者Liu, Chen-Yang
作者单位1.Chinese Acad Sci, Beijing Natl Lab Mol Sci, CAS Key Lab Engn Plast, Joint Lab Polymer Sci & Mat,Inst Chem, Beijing 100190, Peoples R China
2.Catholic Univ Louvain, Unite Chim & Phys Hauts Polymeres, B-1348 Louvain, Belgium
3.TA Instruments, New Castle, DE 19720 USA
4.TA Instruments, D-65760 Eschborn, Germany
推荐引用方式
GB/T 7714
Liu, Chen-Yang,Yao, Minglong,Garritano, Ronald G.,et al. Instrument compliance effects revisited: linear viscoelastic measurements[J]. RHEOLOGICA ACTA,2011,50(5-6):537-546.
APA Liu, Chen-Yang,Yao, Minglong,Garritano, Ronald G.,Franck, Aloyse J.,&Bailly, Christian.(2011).Instrument compliance effects revisited: linear viscoelastic measurements.RHEOLOGICA ACTA,50(5-6),537-546.
MLA Liu, Chen-Yang,et al."Instrument compliance effects revisited: linear viscoelastic measurements".RHEOLOGICA ACTA 50.5-6(2011):537-546.

入库方式: OAI收割

来源:化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。