中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Real time kinetic analysis of the interaction between immunoglobulin G and histidine using quartz crystal microbalance biosensor in solution

文献类型:期刊论文

作者Liu, Y; Yu, X; Zhao, R; Shangguan, DH; Bo, ZY; Liu, GQ
刊名BIOSENSORS & BIOELECTRONICS
出版日期2003-10-01
卷号18期号:11页码:1419-1427
关键词Piezoelectric Biosensor Flow Injection Analysis Kinetic Affinity Constant Immunoglobulin g Histidine
ISSN号0956-5663
DOI10.1016/S0956-5663(03)00090-3
英文摘要Quartz crystal microbalance (QCM) biosensor integrated in a flow injection analysis (FIA) system was used for the investigation of the specific interaction between immunoglobin G (IgG) and histidine. The histidine was immobilized on the gold electrodes of the piezoelectric crystal using appropriate procedures based on self-assembling of the dithiothreitol (DTT). The specific interaction of the immobilized ligand with IgG in solution was followed as a change in the resonant frequency of the modified crystal and studied in real time without any additional labels. With the mass sensitive biosensor system, the differences in affinity of three different species of IgG: human IgG, goat IgG and mouse IgG were easily distinguished and their respective kinetic rate constants (k(ass) and k(diss)) and equilibrium association constants (K-A) were determined from the curves of frequency versus time. For the interactions, K-A were 2.92 x 10(4), 3.23 x 10(4) and 4.08 x 10(4) M-1 for human IgG, goat IgG and mouse IgG, respectively. (C) 2003 Elsevier Science B.V. All rights reserved.
语种英语
WOS记录号WOS:000185193500014
出版者ELSEVIER ADVANCED TECHNOLOGY
源URL[http://ir.iccas.ac.cn/handle/121111/81397]  
专题中国科学院化学研究所
通讯作者Liu, GQ
作者单位Chinese Acad Sci, Inst Chem, Ctr Mol Sci, Beijing 100080, Peoples R China
推荐引用方式
GB/T 7714
Liu, Y,Yu, X,Zhao, R,et al. Real time kinetic analysis of the interaction between immunoglobulin G and histidine using quartz crystal microbalance biosensor in solution[J]. BIOSENSORS & BIOELECTRONICS,2003,18(11):1419-1427.
APA Liu, Y,Yu, X,Zhao, R,Shangguan, DH,Bo, ZY,&Liu, GQ.(2003).Real time kinetic analysis of the interaction between immunoglobulin G and histidine using quartz crystal microbalance biosensor in solution.BIOSENSORS & BIOELECTRONICS,18(11),1419-1427.
MLA Liu, Y,et al."Real time kinetic analysis of the interaction between immunoglobulin G and histidine using quartz crystal microbalance biosensor in solution".BIOSENSORS & BIOELECTRONICS 18.11(2003):1419-1427.

入库方式: OAI收割

来源:化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。