英文摘要Image noise can dramatically affect image processing and hemoglobin oxygen saturation (SO2) calculation accuracy in non-invasive retinal oximetry. Recently, the denoising algorithm based on Variance stabilizing transform (VST) and dual domain filter (DDID) has been proposed to address this issue by our lab. Actually, dual-wavelength retinal images belong to multi-mode images, in order to maximize the use of complementary information at the edges of dual-wavelength images and further reduce the calculation error of SO2, we improve the previous algorithm. Firstly, noise parameters were also estimated by mixed Poisson-Gaussian (MPG) noise model. Secondly, a novel MPG denoising algorithm which we called VST+CDDID was proposed based on VST and cross dual domain filter. To evaluate the proposed algorithm, both simulative and real experiments have been carried out and the results show that the proposed method can effectively remove MPG noise and preserve edge details. Compared with VST+DDID, the proposed method shows great advantage in terms of PSNR, SSIM and visual quality. The following simulation and analysis indicate that the images denoised by VST+CDDID can provide more accurate grayscale values than the images denoised by VST+DDID for retinal oximetry. © 2017 IEEE.
会议录2017 3rd IEEE International Conference on Computer and Communications, ICCC 2017
文献子类C
语种英语
源URL[http://ir.ioe.ac.cn/handle/181551/9120]  
专题光电技术研究所_自适应光学技术研究室(八室)
作者单位1.Chinese Academy of Sciences, Key Laboratory of Adaptive Optics, Chengdu, China;
2.School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu, China;
3.Chinese Academy of Sciences, Institute of Optics and Electronics, Chengdu, China;
4.University of Chinese Academy of Sciences, Chengdu, China
推荐引用方式
GB/T 7714
Xian, Yongli,Dai, Yun. Multi-mode images denoising algorithm for further improving the accuracy of oxygen saturation calculation in the retinal oximetry[C]. 见:. Chengdu, China. December 13, 2017 - December 16, 2017.

入库方式: OAI收割

来源:光电技术研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。